Télécharger Imprimer la page

Franke NEPTUNE FNE 368 TC W Instructions D'installation page 10

Publicité

Les langues disponibles

Les langues disponibles

ELECTRICAL CONNECTION
• Remove the cover from the Field Wiring Compartment with a
phillips screwdriver.
• Feed the Power Supply Cable through the electrical knockout.
Connect the Power Supply Cable to the range- hood cable. At-
tach the Power Supply Cable grounding lead to the green screw
provided. Attach the White lead of the power supply to the
White lead of the rangehood with a twist-on type wire connec-
tor. Attach the Black lead of the power supply to the Black
lead of the rangehood with a twist-on type wire connector.
• Replace the cover.
Upper exhaust Chimney
• Slightly widen the two sides of the upper flue and hook them
behind the brackets 7.2.1, making sure that they are well
seated.
• Secure the sides to the brackets using the 4 screws 12c sup-
plied.
• Make sure that the outlet of the extensions pieces is aligned
with the chimney outlets.
Lower exhaust Chimney
• Slightly widen the two sides of the flue and hook them be-
tween the upper flue and the wall, making sure that they are
well seated.
• Fix the lower part laterally to the hood body using the 2 screws
12c supplied.
EN
Chimney assembly
Green
Ground wire
Ground
screw
Power supply cable
7.2.1
2.1
2
2.2
12c
12c
12c
1
10
0

Publicité