2.
If the included removable grease trough is not already installed within the
hood, insert into the rear inside channel of the hood. Make sure the taller
side of the trough is facing towards the back of the hood (Figure 10).
Grease Trough
Channel
Figure 10
3.
Install the baffle filters along with any spacer bars that are required by
inserting the top of the filter into the top channel of the hood, then slide the
bottom of the filter into the bottom channel. In models with spacers, it is
easiest to install the spacer(s) first and the grease filters last (Figure 11).
Bottom
Channel
Figure 11
SECTION 10
Operation
Controls
Your Range Hood is equipped with two rotary switches with one controlling the
lighting and the other controlling the exhaust fan blower. The light switch has
three positions, HIGH ( ), LOW ( ), and OFF (•). The fan switch has four positions,
OFF (•), HIGH (I), MEDIUM (II), and LOW (III) (Figure 12).
Blower Switch
Figure 12
Trouble
1. Hood does not operate when the switch is on.
2. Hood is operating, but air moves slower than normal.
3. Hood is making a rattling noise.
111597000 Rev. A 5-07
Get user manuals:
See SafeManuals.com
Channel
2
3
1
Light Switch
Heat Lamp Switch
Probable Cause
1a. A fuse may be blown or a circuit tripped. 1a. Replace fuse or reset circuit breaker.
1b. Wiring is not connected properly.
2.
Obstruction in the exhaust ducting.
3a. Filters are loose.
3b. Duct connection is loose.
NOTE: On installation where a One (1) speed blower is utilized, all blower control
speeds operate at the same speed. On installation where a Two (2) speed blower
is utilized, the Medium and High speeds operate at the same speed.
Heat Lamp Controls: For models equipped with heat lamps, two On/Off rocker
switch are located on the front underside of the hood for independent control
of the heat lamps (Figure 12).
SECTION 11
Maintenance
CAUTION:
BEFORE SERVICING THE UNIT.
Grease Baffles - Included with your range hood are aluminum grease
baffles along with a grease trough that should be washed at least once a month.
The baffles and trough are dishwasher safe and should be washed in a mild
soap or detergent. Reverse the instruction in SECTION 9 Finishing the Installation ,
to remove baffles and trough. If the grease baffles become damaged, replace
with Air King Model PHGB1, PHGB2, or PHGB3 Grease Baffles.
CAUTION:
Top
Changing the Lamps: Disconnect power to the unit and unscrew lamps
from socket. Replace with lamps as specified in SECTION 9 Finishing the Installation.
Cleaning
CAUTION:
CLEANSERS, ETC., AS THEY MAY DAMAGE THE RANGE HOOD.
1.
Clean your range hood with a mild detergent, such as dishwashing liquid,
and dry with a soft cloth. NEVER USE ANY ABRASIVE PADS OR SCOURING
POWDERS. Completely dry before restoring power. NEVER IMMERSE
ELECTRICAL PARTS IN WATER.
2.
The blower assembly can be vacuumed when build up (dirt, lint, etc.)
accumulates over time. The blower is permanently lubricated and does
not require oiling.
Troubleshooting Guide
Suggested Remedy
1b. Turn off power to unit. Check that all wires are connected.
2. Check for any obstructions in the ducting including filter.
3a. Turn off power to unit. Check that all filters are fully seated.
3b. Turn off power to unit. Check that duct connection is tight.
www.airkinglimited.com
MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL
ALLOW BULB TO COOL BEFORE REPLACING.
DO NOT USE GASOLINE, BENZINE, THINNER, HARSH
4 of 16