Using the TORX T10 screwdriver remove the 4 screws under the housing.
When removing the screws, be careful of not loosing the O-rings (under
the screws) .
Use a coin to remove the upper part from the lower part using the notch
provided for this purpose.
Rotate the upper part, taking the axis of rotation of the casing on the M8 base
case (opposite side of the notch).
Open carefully the device to
avoid damaging the cable and its
connections
Remove the old battery.
1 - Disconnect the battery
2 - Remove the old battery.
When disconnecting the battery, be
careful not to damage the compo-
nents near the connector
Twist the wires of the battery
(perform 5 rotations) if they are are
not already twisted
Install the new battery supplied by erco-
gener within the empty part of the cas-
ing.. Be careful with its direction in the
casing (shall be the same as the old battery).
Inverser le pliage pour la version française.
The information and non contractual pictures in this document are given for indication purposes
only. ercogener SAS reserves the right to modify its products and documentation at any time.
EG-IoT_K016_IS_000
Dct_425_01