MAIN COMPONENTS:
1. FRAME including water heater hanging bar.
2. SEALED CHAMBER BASE, forming the combustion chamber together with the
cover.
3. FLUE EXTRACTOR UNIT equipped with an extractor body, fan, air pressure
switch and Ø 60-100 coaxial output.
4. FAN for removing combustion gases via the Ø 60 pipe and allowing air from
outside to enter the chamber.
5. HEAT EXCHANGER made of copper.
6. BURNER made of stainless steel with distribution manifold equipped with
injectors in accordance with gas type.
7. ELECTRODES for ignition and ionisation flame sensor.
8. GAS VALVE equipped with two safety valves, manual power selection,
automatic power modulation depending on water flow and progressive
burner ignition.
9. WATER VALVE equipped with automatic water flow regulator and manual
temperature selector.
10. POWER SUPPLY AND CONTROL: Supplies heater with 1.5 V from a 220-230
V
mains voltage. Supplies fan and controls removal of combustion products
AC
via the air pressure switch.
11. ELECTRONIC CIRCUIT for ignition and ionisation flame control.
12. AIR PRESSURE SWITCH which cuts off gas flow to burner in case of fan
malfunction
13. Ø 60-100 COAXIALFLUE SPIGOT
14. SUPPLY CABLE
15. WATER FLOW SWITCH: a safety device to prevent the gas water heater ope-
rating if there is no water flowing.