Models with Oscillating Handle (Part No. 190010A)
Note: Two "O" rings, one 13/16" O.D. and a smaller 3/4" O.D. are packaged loose with this repair kit.
Read the following instructions to determine use, if necessary, of each.
1) Turn off water supply.
2) Loosen set screw securing bonnet.
3) Remove the following and keep for re-use: - handle
4) Remove and DISCARD the following:
- existing TEMPUS II cartridge
- nylon spacer
5) Install new cartridge. (If cartridge shoulder cannot be pushed to within
1/16" of body, remove cartridge and install cartridge spacer over "O"
ring and re-install.) Secure with new capnut.
6) If metering cartridge cannot be installed into body, remove TOP "O"
ring and replace with 13/16" O.D. "O" ring (supplied loose).
7) Place nylon spacer and fibre washer over stem and re-install spring,
handle and bonnet.
8) Secure bonnet with set screw.
9) Turn on water supply.
10) If water drips after cartridge is shut-off, install 3/4" O.D. (packaged
separately) "O" ring over end of metering cartridge against shoulder.
NOTE: Cycle times are factory preset 9 to 16 seconds at 50 PSI. For a shorter
cycle time, reduce push button/handle travel by changing position of timing
adjustment nuts.
CAUTION: DO NOT OVERTIGHTEN CAPNUT. Tighten to 12 ft-lbs (max).
Models with Push Button (Part No. 190009A)
Note: Two "O" rings, one 13/16" O.D. and a smaller 3/4" O.D. are packaged
loose with this repair kit.
Read the following instructions to determine use, if necessary, of each.
1) Turn off water supply.
2) Remove existing TEMPUS II cartridge and push button and discard.
3) Install new TECK cartridge. (If cartridge shoulder cannot be pushed
to within 1/16" of body, remove cartridge and install cartridge spacer
over "O" ring and re-install.) Secure with new capnut.
4) If metering cartridge cannot be installed into body, remove TOP "O"
ring and replace with 13/16" O.D. "O" ring (supplied loose).
5) Place new push button onto cartridge and secure with set screw.
6) Turn on water supply.
7) If water drips after cartridge is shut-off, install 3/4" O.D. (packaged
separately) "O" ring over end of metering cartridge against shoulder.
NOTE: Cycle times are factory preset 9 to 16 seconds at 50 PSI. For
shorter cycle time, reduce push button/handle travel by changing position
of timing adjustment nuts.
CAUTION: DO NOT OVERTIGHTEN CAPNUT. Tighten to 12 ft-lbs (max).
350 South Edgeware Road
St. Thomas, Ontario, Canada N5P 4L1
Tel: 1-800-567-3300 (ENG.)
Tél: 1-800-265-9425 (FR.)
INSTALLATION SHEET
- bonnet
- spring
Metering Faucet Body
Urinal Valve Body
RETROFIT
Urinal Valve Body
Existing TEMPUS II Cartridge
DISCARD
Urinal Valve Body
New Metering Cartridge
Cartridge
Shoulder
Top O-Ring (See 6)
Locate 3/4" O.D. O-Ring here (See 10)
Cartridge Spacer (See 5)
(Retrofit Kit only)
Metering Faucet Body
or
Urinal Valve Body
Timing Adjustment Nuts
Cartridge Shoulder
Top O-Ring (See 4)
Locate 3/4" O.D. O-Ring here (See 7)
or
Box 40980, 55 East 111th Street,
Indianapolis, Indiana 46280
Tel: (317) 848-1812
Website: www.deltacommercialfaucets.com
Nylon Spacer
Spring
Bonnet
Handle
KEEP FOR USE WITH NEW CARTRIDGE
New Capnut
New Nylon Spacer
Spring
Bonnet
New Fibre Washer
Timing Adjustment Nuts
TEMPUS II Metering Cartridge
Push Button
DISCARD
New Push
Button
New Capnut
New Metering Cartridge
Cartridge Spacer (See 3)
(Retrofit Kit only)
200798 Rev. B
Handle

Publicité

loading

Sommaire des Matières pour Delta TECK 190010A

  • Page 1 RETROFIT INSTALLATION SHEET Models with Oscillating Handle (Part No. 190010A) Note: Two “O” rings, one 13/16” O.D. and a smaller 3/4” O.D. are packaged loose with this repair kit. Read the following instructions to determine use, if necessary, of each. 1) Turn off water supply.
  • Page 2 INSTRUCTIONS D’INSTALLATION POUR LA CARTOUCHE DE MODIFICATION Modèles à manette oscillante (Pièce N° 190010A) Note : Deux joints toriques (emballés à même) sont fournis avec cette trousse de modification. L’un a un diamétre ext de 13/16 po, l’autre, plus petit a 3/4 po. Lire les instructions afin d’en connaître l’utilisation, si nécessaire.
  • Page 3 HOJA DE INSTRUCCIONES PARA LA INSTALACIÓN DEL CARTUCHO ACTUALIZADO Modelos con manija oscilante (No. de pieza 190010A) Nota: Dos anillos “O”, uno de 13/16” D.E. y uno más pequeño de 3/4” D.E. están embalados sueltos en este juego de reparación. Lea las siguientes instrucciones para determinar el uso, si es necesario, de cada uno. 1) Cierre el suministro de agua.

Ce manuel est également adapté pour:

Teck 190009a