Technical description
The mains rectifier can operate all coolers and refrigerators with BD35F compressors
at 230 V. With a 230 V mains connection, the rectifier automatically switches from
battery to mains operation.
When disconnected from the 230 V mains supply, the rectifier automatically
switches back to battery operation. Mains operation via the rectifier always takes
priority over battery operation.
5.1
Control elements
Item in
fig. 1,
Explanation
page 3
1
Mains cable
2
Fastening bracket
3
Self-tapping screws
4
12 V socket
Glass fuse (250 V, 10 A, ceramic)
5
6
Compressor output terminals
7
Battery input terminals
6
Mounting the mains rectifier
If you wish to mount the mains rectifier in a fixed position, please observe the
following mounting instructions:
Do not mount the device
– In wet or damp environments
– In the vicinity of combustible materials
– In areas where there is a danger of explosions
The place of installation must be well-ventilated. A ventilation system which is at
least equivalent to the air openings in the device must be present for installations
in closed housings.
The air intake on the underside or the air outlet on the back of the device must
remain clear.
The installation surface must be level and sufficiently sturdy.
EN
Technical description
9