EPS100
5
Technical description
The mains rectifier can operate all coolers and refrigerators with BD35F compressors
at 230 V. With a 230 V mains connection, the rectifier automatically switches from
battery to mains operation.
When disconnected from the 230 V mains supply, the rectifier automatically
switches back to battery operation. Mains operation via the rectifier always takes
priority over battery operation.
5.1
Control elements
Item in
fig. 1,
Explanation
page 3
1
Mains cable
2
Fastening bracket
3
Self-tapping screws
4
12 V socket
Glass fuse (250 V, 10 A, ceramic)
5
6
Compressor output terminals
7
Battery input terminals
6
Mounting the mains rectifier
If you wish to mount the mains rectifier in a fixed position, please observe the
following mounting instructions:
•
Do not mount the device
– In wet or damp environments
– In the vicinity of combustible materials
– In areas where there is a danger of explosions
•
The place of installation must be well-ventilated. A ventilation system which is at
least equivalent to the air openings in the device must be present for installations
in closed housings.
•
The air intake on the underside or the air outlet on the back of the device must
remain clear.
•
The installation surface must be level and sufficiently sturdy.
EN
Technical description
9