Functional Test - Protector AS-6030.3 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

3. Insert the battery (CR 2477) in the window TRANSMIT-
TER (4). The LED (5) on the transmitter lights up briefly.
4. Activate the window TRANSMITTER by holding the
magnet once on the housing and removing it again.
The LED integrated in the transmitter lights up. At the
RECEIVER the LED Status (3) now lights up red and the
teach-in process is completed.
5. Press the RECEIVER button (2) again for 2 seconds, the
LED Status (3) begins to flash.
6. Place the batteries (3x AAA) in the FURNACE TRANSMIT-
TER (7). The LEDs on the transmitter (10 and 11) light
up briefly.
7. Activate the FURANCE TRANSMITTER (7) by pressing
the Status button (9) once. The LEDs integrated in the
transmitter light up. The LED Status (3) lights up green
on the RECEIVER and the teach-in process is completed.
After that the LED Status (3) turns to red and green.
8. You can set the current furnace status (hot or cold) by
pressing the Status button (9) on the furnace transmit-
ter (7). However, this is also automatically transmitted
during the next status change.
9. The TRANSMITTERS on the RECEIVER are now taught in
and the AS-6030.3 is ready for use.
TEACHING IN MULTIPLE TRANSMITTERS
(MAX. 8 ITEMS)
1. Press the button (2) on the receiver for 2 seconds. The
LED Status (3) begins to flash red.
2. Place a battery / the batteries in the TRANSMITTER to
be taught in.
3. Activate the TRANSMITTER to be deleted by holding the
magnet once on the housing and removing it again or
pressing the Status button. The LED Status (3) stops
flashing on the RECEIVER and the teach-in process is
completed.
4. Repeat steps 1), 2) and 3) for each individual
transmitter.
5. If max. 8 TRANSMITTERS are taught in, no further
transmitters can be added.
DELETING individual or all TRANSMITTERS
Deleting individual TRANSMITTERS
1. Press the button (2) on the receiver for 2 seconds. The
LED Status (3) begins to flash red.
2. Activate the TRANSMITTER to be deleted by holding the
magnet once on the housing and removing it again or
pressing the Status button. The LED Status (3) stops
flashing on the RECEIVER and the deletion is completed.
Deleting all TRANSMITTERS
1. Press the button (2) on the receiver for 2 seconds. The
LED Status (3) begins to flash red.
2. Press the button (2) for 2 seconds again. The LED Status
(3) stops flashing on the RECEIVER and the deletion is
completed for all TRANSMITTERS.

FUNCTIONAL TEST

The temperature at the thermo-sensor (8) of the furnace
transmitter (7) is crucial for the function testing of the
exhaust air control.
Thermo-sensor (8) of the furnace transmitter
is < 38°C
1. Switch ON exhaust unit and window is closed
> Exhaust unit must start up.