2. Insert the battery with correct polarity into the window
transmitter (4) lower section. Note: Make sure that the
battery of the transmitter is placed on the metal tie bar
and do not slide it below this.
3. Press the housing upper section of the window transmit-
ter onto the housing lower section.
4. Mount the housing lower section with the magnet (6) at
the intended location with the enclosed adhesive pad.
A TTENTION: The distance between the transmitter and
magnet must not exceed 7 mm and please ensure a firm
and correct fit of the individual components.
5. Insert magnet and close with the magnet housing upper
section (6).
MINIMUM WINDOW OPENING
Before installation you should determine the minimum
opening of the monitored window which is based on:
a) The power of the exhaust air device in m³/h
b) The size of the window to be opened in m²
c) The size of the window opening in cm (see table 1)
Most kitchens have rectangular tilt and pivot windows.
If your window is round for example, please ask the
installation and heating engineers or electrician to calculate
the minimum opening.
The minimum opening of rectangular windows is shown as
an example in the table for the tilt and pivot position.
Calculation table to determine the minimum opening
of your window
1. Determine the extraction power of your exhaust air
extraction device unit in m³/h. You can find the exhaust
air extraction power on the identification plate or in the
operating instructions of your exhaust air device (e.g.
extractor hood).
2. Measure the inner width and height of the window and
calculate the window size in m².
(width x height = m²; e.g. 0.8 m x 1.0 m = 0.8 m²) =
window size
3. Using the table, work out the opening size (minimum
opening for your window) from the extraction power and
window size.
4. While the window is in the titled position, measure the
upper inner gap size of the window in cm. The gap size
of your window must not be below the opening size
calculated! The bigger the gap or window opening,
the better.
5. If the gap size of the window is less than the permissible
value for the opening size according to the table, the
window may only be able to achieve the required
opening size in the pivot position. There must also be a
minimum gap when the window is in the pivoted posi-
tion. The window contact shall be positioned in such a
way as to ensure the minimum gap size. We recommend
you ensure the minimum gap size using a spacer.
ASSEMBLY OF THE FURNACE SENSOR
Assembly instructions for furnace transmitter (7) including
thermo-sensor (8)
19
ENGLISH | AS-6030