Télécharger Imprimer la page

hager tebis TX 320 Notice D'instructions page 2

Publicité

Les langues disponibles

Les langues disponibles

tebis
/
User instructions
Usage
The thermostat TX 320 KNX/EIB is used for
controlling the temperature in individual rooms
of functional and private buildings.
It is a proportional integral (PID) control.
It is also possible to control 2-step heating
(basic and additional step) as well as heating
and cooling systems.
The thermostat should be used in dry rooms.
Configuration
● TX 100 V1.6.3 or higher: detailed description
is included in User's Instructions supplied
with the configurator.
● ETS : application software TL 320A,
database and description available from the
manufacturer.
Description of thermostat
Push button for operating modes or
presence.
comfort mode
standby mode
reduction mode (in the night)
frost protection
red/blue LED:
red = heating
blue = cooling
out = demanding temperature is reached.
Temperature selector.
Installation
Hager Electro S.A.S. - 132, bld d'Europe - BP3 - 67 215 Obernai cedex - Tél. 03.88.49.50.50 - www.hager.com
TX 320
Thermostat d'ambiance
F
Room thermostat
GB
Raumthermostat
D
Thermostaat van
NL
kamertemperatuur
TP
GB
Installation
Connection - Installation
5-6mm
1
2
5
6
9
10
Installation of thermostat
1. Gently pull-off the temperature
selector.
2. Turn the latch with a small screwdriver
to position "OPEN".
3. Carefully place thermostat
on the guiding rails and
push to the left until
mounting base is covered.
Do not tilt thermostat!
4. Turm latch with a small screwdriver
to position "CLOSE".
5. Place temperature selector on the
unit.
De-Installation
De-installation of thermostat
1. Draw off temperature selector.
2. Loosen latch to position "OPEN".
3. Push thermostat to the
right and left the unit.
Do not tilt thermostat!
Bus
RF
230V~
30 V
3
4
7
8
11
4
3
5
2
6
1 .
2 .
°C
OPEN
CLOSE
1 .
2 .
OPEN
CLOSE
1 .
2 .
OPEN
CLOSE
4
3
5
2
6
1 .
2 .
°C
OPEN
CLOSE
4
3
5
2
6
°C
1 .
2 .
OPEN
CLOSE
1 .
2 .
OPEN
CLOSE
De-installation of mounting base
1. Press-in spring at cover of the
mounting base and lift it off.
2. Loosen screws and reverse base
unit.
3. To pull out wire use an
appropriate screwdriver
to release spring clamp!
Temperature
Button for adjusting the temperature setpoint
within ± 2°C (default setting).
20
1
2
20
20
4
5
Connection of BUS and inputs
E3
E3
E2
E2
E1
E1
COM
COM
BUS
Functionality of inputs :
Inputs (E1-E3) are used to interface
contacts free of potential with EIB/KNX
bus, such as pushbuttons, switches or
conventional automatisms.
The particular functions of each product
18
2
1 6
depend on the configuration and the set-up.
Connect the bus cable to the bus line
(red + / black –). (Note the polarity!)
Entering the physical address
18
2
1 6
Technical characteristics
- Power supply:
- Power consumption:
- Operating temperature:
18
2
1 6
- Storage temperature:
- Protection type:
- This device must be installed only by
a qualified electrician.
- Conform to TBTS installation rules.
2
20
3
max.
OPEN
CLOSE
6
min.
Set physical
address.
Programming
LED.
bus KNX/EIB
30V DC TBTS
< 10 mA
0 °C —> +45 °C
-20 °C —> +60 °C
IP21
6T 6091.a