Télécharger Imprimer la page

AEG ELFAMATIC uC 3000 Notice D'utilisation Et De Montage page 28

Masquer les pouces Voir aussi pour ELFAMATIC uC 3000:

Publicité

Les langues disponibles

Les langues disponibles

For the Fitter
Button
P
P
P
M
3x
Factory setting:
1.5 Test function
The storage heater can be checked in the TEST menu.
Button
M
for approx.
3 sec.
M
2x
P
3x
28
All manuals and user guides at all-guides.com
LCD
Button
+
VR LF LZ KU
SYNC
ED
AS
SH
SYN
+
VR LF LZ KU
S LF
ED
SH
SYN
+
VR LF LZ KU
SAVE
ED
SH
SYN
VR LF LZ KU
14 : 53
14 : 53
ED
SH
SYN
LCD
Button
INST
VR LF LZ KU
ED
SH
SYN
TEST
VR LF LZ KU
ED
SH
SYN
+
VR LF LZ KU
LDT
ED
AUS
SH
SYN
Note
Important parameters for synchronisation.
or
AS = Autosynchronisation. The controller synchronises auto-
matically with the charging release if the main release
comes later than defined in the parameter "S LF".
PO = Powertherm charging system. The controller synchronises
automatically with the charging release and, with con-
tinuously applied LF, internally simulates interruption of
the charging release at the 24 hours previously deter-
mined time points for 48 hours.
LF = Synchronisation with the charging release. The controller
synchronises with the charging release signal. If "LF" is
selected, the number of hours which have passed since
the charging release must be set in the user menu instead
of the time (during normal operation, the display changes
from UHR/AF to LA/AF).
Time of earliest possible main release.
or
Caution: If in the case of certain charging models from the
power supply companies an additional release is given very late,
the parameter "S LF" must be set to a time after the additional
release, e.g.:
additional release from 21:00 to 23:00 – Set "S LF" to at least 22.
The set parameters can be stored so that they can be called up
or
again after temporary parameter changes.
The set parameters are stored by holding down the
for longer than 3 seconds. If required, the parameters stored in
this way can be called up again by holding down the
for longer than 3 seconds.
Manual setup of the controller is now complete. The controller
is ready for operation.
A reset to the factory setting is made by pressing
the - and + keys in the INST menu simultaneously for more
than 3 seconds.
Note
TEST menu
Parameters for testing the control line and the charging
or
controllers in the storage heaters.
AUS = Function disabled
0 %
= Control signal for charging suppression is output
100 % = Control signal for full charging is output
+
button