Before taking into operation for the first time, the installation has to be approved by an expert!
OPERATION
After you connected the spot to the mains, you can control the spots via your lighting controller.
CLEANING AND MAINTENANCE
The operator has to make sure that safety-relating and machine-technical installations are inspected by an
expert after every four years in the course of an acceptance test.
The operator has to make sure that safety-relating and machine-technical installations are inspected by a
skilled person once a year.
The following points have to be considered during the inspection:
1) All screws used for installing the devices or parts of the device have to be tighly connected and must not
be corroded.
2) There must not be any deformations on housings, fixations and installation spots (ceiling, suspension,
trussing).
3) The electric power supply cables must not show any damages, material fatigue (e.g. porous cables) or
sediments. Further instructions depending on the installation spot and usage have to be adhered by a
skilled installer and any safety problems have to be removed.
We recommend a frequent cleaning of the device. Please use a moist, lint-free cloth. Never use alcohol or
solvents!
The interior of the device should be cleaned at least annually using a vacuum-cleaner or an air-jet.
There are no serviceable parts inside the device except for the lamp. Maintenance and service operations
are only to be carried out by authorized dealers.
Please refer to the instructions under "Installing/Replacing the lamp".
Should you need any spare parts, please use genuine parts.
If the power supply cable of this device becomes damaged, it has to be replaced by authorized dealers only
in order to avoid hazards.
Should you have further questions, please contact your dealer.
TECHNICAL SPECIFICATIONS
Power supply:
Power consumption:
Dimensions (LxWxH):
Weight:
Maximum ambient temperature t
Maximum housing temperature t
Minimum distance:
Accessory:
OMNILUX PAR-20 240V/75W E27 spot
OMNILUX PAR-20 240V/75W E27 flood
Barn doors PAR-20, black
Please note: Every information is subject to change without prior notice. 30.05.2005 ©
DANGER TO LIFE!
DANGER TO LIFE!
Disconnect from mains before starting maintenance operation!
230 V AC, 50 Hz ~
75 W
180 x 125 x 145 mm
0.3 kg
:
45° C
a
:
120° C
B
0.5 m
No. 88021005
No. 88021105
No. 42103600
17/32