6 electrolux
• This appliance is supplied with a mains
cable. It has to be supplied with a correct
plug, able to support the load marked on
the rating plate. The plug has to be fitted
in a correct socket.
• Any electrical component must be instal-
led or replaced by the Service Force
Centre technician or qualified service per-
sonnel.
• Always use a correctly installed shock-
proof socket.
• Make sure that there is an access to the
mains plug after installation.
• Do not pull the mains cable to disconnect
the appliance. Always pull the mains
plug.
• The appliance must not be connected
with an extension cable, an adapter or a
multiple connection (risk of fire). Check
that the ground connection is in conform-
ity with the standard and regulations
force.
• The power cable must be placed in such
a way that it does not touch any hot part.
• Connect the appliance to the mains with
a device that lets to disconnect the appli-
ance from the mains at all poles with a
contact opening width of minimum 3
mm, eg. automatic line protecting cut-
out, earth leakage trips or fuse.
• None of a parts of the connection cable
can not get a temperature 90 °C. The
blue neutral cable must be connected to
the terminal block label with "N". The
brown (or black) phase cable (fitted in the
terminal block contact marked with "L")
must always be connected to the live
phase.
Replacement of the connection cable
To replace the connection cable use only
H05V2V2-F T90 or equivalent type. Make
sure that the cable section is applicable to
the voltage and the working temperature.
The yellow/green earth wire must be ap-
proximately 2 cm longer than the brown (or
black) phase wire.
All manuals and user guides at all-guides.com
Building In
min. 600 mm
min. 450 mm
min. 55 mm
30 mm
480 mm
B
A) supplied seal
B) supplied brackets
Possibilities for insertion
Kitchen unit with door
The panel installed below the hob must be
easy to remove and let an easy access in
case a technical assistance intervention is
necessary.
min. 650 mm