1
.
Turn on the torque tester (COD.57650 Torque tester SQ 1/2''___35-350 Nm).
- Press C to turn on the torque tester.
- Often press to reset the torque tester before use.
2
.
Open the safety cover to proceed with the installation of the torque wrench.
3
.
Place the torque wrench in the position of the torque tester you will be using. The use of
an adapter may be required to connect the square drive of the torque wrench to the tester.
4
.
The torque wrench must be placed in a horizontal position.
Then slide the pusher fig.2 (COD.RA177) horizontally so that it is located between the rear
part and the handle of the wrench. It will always be placed at the height of the middle of the
handle, which is where the application point is located to achieve the required torque.
Close the safety cap.
5
.
Make sure the torque tester to be used is turned on.
6
.
As you start turning the crank to the right, load the key. The rotation must be continuous
until the torque wrench reaches the selected torque. At that time the torque value on the
tester will be fixed.
After the test is complete, make a note of the test torque value indicated on the torque
tester display.
Turn the crank counterclockwise until the torque wrench is in the free (no load) position.
In case of CCW calibration, place the tool fig.10 in torque wrench housing at required
position and follow previous procedure for calibration.
12
QUICK USE GUIDE
Before starting the calibration:
-
the torque wrench must not be loaded.
-
the right end of the torque wrench housing must be at the rear
end of the spindle (move it backwards with the handle).
For more information on torque testers
see instructions at: www.egamaster.com