Télécharger Imprimer la page

Solar PI30000X Guide D'utilisation page 15

Onduleur électrique, sonic compression

Publicité

Les langues disponibles

Les langues disponibles

Problem:
Low Battery Alarm on Continuously
Answer:
The voltage of the 12 Volt power source may have dropped below 10.5 Volts – check 12 Volt power
source voltage and recharge as needed.
Answer:
Poor or weak 12 Volt power source – recharge or replace the battery.
Answer:
Inadequate power delivery from the 12 Volt power source – check the connections between
the 12 Volt power source and the power inverter (see "Connect the DC Input Cables").
Problem:
Poor Television/Audio Device Reception
Answer:
Refer to "Suggestions When Using Your Power Inverter to Power Television and Audio Devices"
section within this Operator's Manual.
Specifications
Model No.
Electrical Specifications
Nominal DC Inpu t
Input Voltage Range
Low Voltage Alarm (10.5V)
Low Voltage Shut-Down (10V)
Over Voltage Shut-Down (15V)
Over Heat Protection (149˚F)
Cooling Fan
Overload Protection
Short Circuit Protection
No Load Current Draw
DC Fuse
AC Output Voltage
AC Output Frequency
Output Waveform
Maximum continuous AC Power
Maximum peak AC Power
Peak Capacity (Seconds)
Efficiency
Operating Temp. Range
LED Indicators
Power Display
AC Receptacle
Individually Switched Outlets
Remote Switch
DC Connection
Dimensions (H x W x L)
Weight
Warranty
SOLAR Power Inverter USER'S MANUAL
PI30000X
12VDC
10 - 15VDC
YES
YES
YES
YES
YES
YES
YES
<0.8 A
18 x 20A
115VAC (RMS) +/-10%
60 Hz +/-3 Hz
Modified sine wave
3000W
6000W
1
>85%
23˚-104°F (-5°-40°C)
Power, Fault
Yes
Triple
Yes
Yes
Hardwire
16.5" x 10.3" x 3.7"
13.20 lbs. (5.99 kg)
One year limited
15

Publicité

loading