Télécharger Imprimer la page

Madeira 10604861 Manuel D'utilisation page 44

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 7
Overview
Control
1
Protective grille
2
Fan blades
3
Wheels
4
Supply cord
5
Fixing screws
6
Handles
7
Intended use
The appliance is intended for distribu-
tion of dry air in private interiors). The
appliance is not intended for commer-
cial use.
Any other use or modification to the
appliance is considered as improp-
er use and could cause considerable
dangers.
Technical data
Art. no
Nominal voltage
Rated power
Ventilator diameter
Speed settings
Protection Class
Degree of protection
Weight
Maximum fan flow rate (F)
Fan power input (P)
Service value (SV)
Maximum air velocity (c)
Measurement standard for SV
Standby power consumption (Q)
Fan sound power level (L
)
WA
Contact for information
86
EN
Use
Adjusting the Air Flow
Tilt the ventilator upwards or down-
wards into the required angle. Fix the
position by tightening the fixing screws
6 firmly. The ventilator can be used in
combination with air conditioning. If
the ventilator is tilted upwards, the air
at ground level is aspirated and subse-
quently distributed into the room.
Ventilator Speed
The ventilator speed can be adjusted
on the control 1 on the backside of the
ventilator:
1
= low speed
2
= medium speed
3
= high speed
0
= ventilator off
10604861 / 10604862 (CH)
220-240 V~ / 50 Hz
124 W
61 cm
Low - Med - Hi - Off
/ I
IPX0
10.5 kg
111.72 m
/min
3
119.1 W
0.94 (m
/min)/W
3
3.381 m/s
EN IEC 60879:2019
38.112 kWh/a
73.5 dB(A)
Zhongshan Reffon Electric Co., Ltd.
Heping Village, Dongfu Road,
Dongfeng Town 528425 Zhongshan
People´s Republic China
Mounting the wheels
1
Insert the wheel axle to the
wheel mount on the frame.
3
Mount the wheels 4 onto the re-
spective ends of the wheel axle.
Air flow
1
Tilt the ventilator to adjust
the air flow upwards or down-
wards. Fix the position by tigh-
tening the fixing screws 6 firm-
ly.
Speed
1
Set the required speed by pres-
sing the corresponding button
on the control 1 on the backside
of the ventilator.
Transport
1
Pick up the ventilator
by the
handles 7 only.
2
Fix the wheel axle by sticking
four of the split pins through
the respective holes in the axle.
4
Secure the wheels 4 with the
two remaining split pins. Make
sure the ends of all six split pins
are bent apart.
2
Insert the power supply cord 5
into a suitable wall socket. For
Switzerland, only use the venti-
lator 10604862.
2
To switch off the ventilator,
press the button 0 on the con-
trol 1.
Storage
2
After use pull the supply cord 5
out of the wall socket and wind
the cable onto the holder on the
backside.
EN
87

Publicité

loading

Ce manuel est également adapté pour:

10604862