SERIES "ABG"
SWIMMING POOL PUMP
O
W
N
E
R ' S
M
A N
U
A L
INSTALLATION, OPERATION & PARTS
Pentair Water Pool and Spa, Inc.
© 2007 Pentair Water Pool and Spa, Inc. All rights reserved.
1620 Hawkins Ave., Sanford, NC 27330 • (919) 566-8000
10951 West Los Angeles Ave., Moorpark, CA 93021 • (805) 553-5000
The Pentair Water Pool and Spa logo is a trademark of Pentair Water Pool and Spa, Inc. Other trademarks and trade names may
be used in this document to refer to either the entities claiming the marks and names or their products. Pentair Water Pool and Spa Inc.
disclaims proprietary interest in marks and names of others.
Printed in U.S.A.
S486 (Rev. A)
02/07/2007

Publicité

loading

Sommaire des Matières pour Pentair Water Pool and Spa STA-RITE ABG Serie

  • Page 1 The Pentair Water Pool and Spa logo is a trademark of Pentair Water Pool and Spa, Inc. Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products. Pentair Water Pool and Spa Inc.
  • Page 2 All manuals and user guides at all-guides.com This manual should be furnished to the end user of this pump; its STA-RITE “ABG” SERIES use will reduce service calls and chance of injury and will lengthen pump life. SWIMMING POOL PUMP To avoid unneeded service calls, prevent possible injuries, and get the most out of your pump, READ THIS MANUAL CAREFULLY!
  • Page 3 All manuals and user guides at all-guides.com owner's manual when installing and operating equipment. Allow use of short, direct suction pipe (To reduce friction losses). Have a trained pool professional perform all pressure tests. Allow for gate valves in suction and discharge piping. Have adequate floor drainage to prevent flooding.
  • Page 4 All manuals and user guides at all-guides.com ELECTRICAL Use the load circuit breaker as the master on-off switch. Install a Ground Fault Circuit Interrupter (GFCI) in circuit; To avoid dangerous or fatal electrical shock, it will sense a short-circuit to ground and disconnect turn OFF power to motor before working on power before it becomes dangerous to pool users.
  • Page 5 All manuals and user guides at all-guides.com OPERATION Pool Water: Keep water level at least two inches above bottom of NEVER run pump dry! Running pump dry may skimmer opening when system is not in use. Failure to do damage seals, causing leakage and flooding! Fill so can allow air to enter system, causing pump to lose its pump with water before starting motor.
  • Page 6 All manuals and user guides at all-guides.com Draining Pump: To avoid dangerous or fatal electrical shock hazard, turn OFF power to motor before work- To avoid dangerous or fatal electrical ing on pump or motor. shock hazard, turn OFF power to motor before drain- No lubrication or regular maintenance is needed beyond ing pump.
  • Page 7 All manuals and user guides at all-guides.com 6. Carefully remove four motor throughbolts from seal Installing New Seal: plate (Figure 4); remove seal plate and use a screw- 1. Ceramic seat must be clean and free of dirt, grease, driver to tap ceramic seat out from the rear (Figure 5). dust, etc.
  • Page 8 All manuals and user guides at all-guides.com TROUBLESHOOTING GUIDE Circuit Breaker In Home Panel Trips Repeatedly: Read and understand safety and operating instructions in this manual before doing any 1. Breaker must be of adequate capacity. work on pump! 2. For GFCI breaker, test according to GFCI manufac- turer’s instructions.
  • Page 9 All manuals and user guides at all-guides.com REPAIR PARTS LIST Part Part Description Qty. 3345 1198 Motor Chart at Right Slinger C69-2 Seal Plate 17500-0001 Seal Plate O-Ring 35505-1438 Shaft Seal U109-358SS Impeller Chart at Right Floating Wear Ring 17500-0004 Trap Body 17500-0002 Trap Lid...
  • Page 10 All manuals and user guides at all-guides.com REPAIR PARTS LIST 3345 1198 CAN Part Part Description Qty. End Cap Screw 37337-0085 End Cap and Cord Assembly 17290-0026 Toggle Switch 16920-0511 Toggle Switch Boot 32800-0107 Baffle Ring 17290-0004 Motor Chart at Right Motor Cover 17190-0021 Parts are common to all models listed except as noted:...
  • Page 11 All manuals and user guides at all-guides.com For technical information about this product, contact the installer or call PENTAIR at (800) 831-7133. Visit www.pentairpool.com and www.staritepool.com 02/07/2007 S486 (Rev.A)
  • Page 12 All manuals and user guides at all-guides.com BLANK PAGE...
  • Page 13 The Pentair Water Pool and Spa logo is a trademark of Pentair Water Pool and Spa, Inc. Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products. Pentair Water Pool and Spa Inc.
  • Page 14 All manuals and user guides at all-guides.com Cette Notice doit être remise à POMPE POUR PISCINE l'utilisateur de cette pompe; elle servira à réduire les appels de STA-RITE, SÉRIE «ABG» dépannage et les possibilités de blessures, de même qu'à pro- longer la durée de la pompe.
  • Page 15 All manuals and user guides at all-guides.com Doit permettre de poser l'aspiration d'eau au niveau de l'eau ou Un équipement mal installé ou mal contrôlé sous le niveau de l'eau de la piscine. peut tomber en panne, causer de graves blessures ou des dommages matériels.
  • Page 16 All manuals and user guides at all-guides.com Raccords : cuit, ne pas oublier d’ajouter leur charge en ampères à la charge en ampères de la pompe avant de déterminer le calibre Les raccords limitent la circulation de l’eau; pour obtenir la du disjoncteur.
  • Page 17 All manuals and user guides at all-guides.com FONCTIONNEMENT Eau de la piscine: Garder le niveau de l’eau au moins à deux pouces au-dessus NE JAMAIS faire fonctionner la pompe à sec! Le fonc- de la partie inférieure de l’ouverture de l’écumoire lorsque le tionnement à...
  • Page 18 All manuals and user guides at all-guides.com Vidage de la pompe: Pour éviter tout risque de secousses élec- triques dangereuses ou mortelles, INTERROMPRE l’arrivée de Afin d’éviter tout risque de secousses élec- courant parvenant au moteur avant d’intervenir sur la pompe ou triques dangereuses ou mortelles, INTERROMPRE le sur le moteur.
  • Page 19 All manuals and user guides at all-guides.com 6. Prudemment, déposer les quatre boulons traversants du Pose d’une bague d’étanchéité neuve: moteur de la plaque d’étanchéité (voir la Figure 4); déposer 1. Le siège en céramique doit être propre et débarrassé de la plaque d’étanchéité...
  • Page 20 All manuals and user guides at all-guides.com GUIDE DE DIAGNOSTIC DES PANNES PANNES DE LA POMPE, CAPACITÉS OU PRESSIONS DE Le disjoncteur du panneau de la maison se déclenche RETOUR RÉDUITES constamment: Prise d’air dans les tuyauteries d’aspiration/perte 1. Le disjoncteur doit être d’une capacité adéquate. d’amorçage: 2.
  • Page 21 All manuals and user guides at all-guides.com LISTE DES PIÈCES DE RECHANGE Désignation N° des Réf. des pièces Qté pièces Moteur Tableau de droite 3345 1198 Déflecteur C69-2 Plaque d’étanchéité 17500-0001 Joint torique de la plaque d’étanchéité 35505-1438 Joint de l’arbre U109-358SS Impulseur Tableau de droite...
  • Page 22 All manuals and user guides at all-guides.com LISTE DES PIÈCES DE RECHANGE 3345 1198 CAN Désignation N° des Réf. des pièces Qté pièces Vis du couvercle d’extrémité 37337-0085 Couvercle d’extrémité et cordon électrique 17290-0026 Interrupteur à bascule 16920-0511 Soufflet de l’interrupteur à bascule 32800-0107 Bague déflectrice 17290-0004...
  • Page 23 All manuals and user guides at all-guides.com Pour obtenir les données techniques du produit, communiquez avec l’installateur ou appelez PENTAIR au numéro (800) 831-7133. Visitez notre site Web : www.pentairpool.com www.staritepool.com 02/07/2007 S486 (Rev.A)
  • Page 24 All manuals and user guides at all-guides.com NOTES 02/07/2007 S486 (Rev.A)