GENERAL RECOMMENDATIONS
The warranty of the generator does not cover items
that have been subjected to operator abuse or negli-
gence. To receive full value from the warranty, opera-
tor must maintain the generator as instructed in this
manual.
Some adjustments will need to be made periodically to
maintain your generator.
GENERATOR MAINTENANCE
Your generator should be kept clean and dry at all
times. The generator should not be stored or oper-
ated in environments that include excessive moisture,
dust or any corrosive vapors. If these substances are
on the generator, clean with a cloth or soft bristle
brush. Do not use a garden hose or anything with
water pressure to clean the generator. Water may
enter the cooling air slots and could possibly damage
the rotor, stator and the internal windings of the
generator head.
All adjustments in the Maintenance section of this
manual should be made at least once each season.
ENGINE MAINTENANCE
NOTICE: Maintenance, replacement or repair of
the emission control devices and systems may be
performed by any nonroad engine repair establish-
ment or individual. However, to obtain no charge
repairs under the terms and provisions of the
engine manufacturers warranty statement, any
service or emission control part repair or replace-
ment must be performed by a factory authorized
dealer.
Oil
•
Oil level should be checked prior to each use and
at least every 8 hours of operation. To check oil
see Adding Engine Oil paragraph in the Opera-
tion section of this manual.
Changing Engine Oil
For a new engine, change oil after the first 5 operating
hours. Thereafter, change oil after every 50 hours of
operation.
Change the oil while the engine is still warm. The oil
will flow freely and carry away more impurities. Make
sure the engine is level when filling, checking or
changing oil.
Change the oil as follows:
•
To keep dirt, grass clippings, etc. out of the
engine, clean the area around the drain plug and
dipstickbefore removing it.
•
Disconnect spark plug wire and keep away from
spark plug. Disconnect battery at negative
terminal.
•
With engine off but still warm, remove oil drain
plug and drain oil into appropriate receptacle.
MGP-670070
All manuals and user guides at all-guides.com
•
•
•
Change Oil Filter
Change oil filter after every 100 hours or every season.
•
•
•
18 — ENG
Used oil is a hazardous
waste product. Dispose of used oil properly.
Do not discard with household waste. Check
with your local authorities, service center, or
dealer for safe disposal/recycling facilities.
Reinstall drain plug. Remove oil fill cap.
Fill the crankcase with new oil of the proper type
(See Adding Engine Oil in the Operation section),
to the FULL mark on the dipstick. Always check
the level with the dipstick before adding more oil.
Reinstall the oil fill cap or plug and tighten se-
curely.
Drain engine oil and remove oil filter.
Used oil is a hazardous
waste product. Dispose of used oil properly.
Do not discard with household waste. Check
with your local authorities, service center, or
dealer for safe disposal/recycling facilities.
Before installing new filter, lightly oil filter gasket
with fresh, clean oil.
Screw filter on by hand until gasket contacts oil
filter adapter. Tighten 1/2 to 3/4 turn more.
Oil Drain Plug
FULL
Filter