To Start Your Generator
Never run engine indoors or
in enclosed, poor ventilated areas. Engine
exhaust contains carbon monoxide, an
ordorless and deadly gas.
IMPORTANT: Make sure the battery is properly
serviced, fully charged, and assembled before starting.
•
Open the fuel shut-off valve.
•
Pull choke control out to CHOKE position.
NOTE: No choke is required on warm engines. Push
choke control in to start a warm engine.
You MUST unplug any load
from the generator before starting to prevent
permanent damage to any appliances.
For electric start:
•
Place OFF/RUN/START switch in the START
position.
NOTE: When the engine starts the switch will
remain in the RUN position.
OFF
RUN
MARCHE
ARRÊT
MGP-670070
All manuals and user guides at all-guides.com
START
DÉMARRAR
16 — ENG
For recoil start:
•
Place OFF/RUN/START switch in the RUN posi-
tion.
OFF
ARRÊT
MARCHE
•
Grasp handle on rope starter and pull slowly until
resistance is felt. Let the rope rewind slowly. Pull
rope with a rapid full arm stroke. Let rope rewind
slowly. Repeat if necessary.
NOTE: IF ENGINE OIL LEVEL IS TOO LOW, EN-
GINE WILL NOT START. CHECK OIL LEVEL AND
ADD IF NECESSARY.
•
When engine warms up, gradually push choke
control in to the NO CHOKE position.
IMPORTANT: Allow generator to run at no load
for 5 minutes upon each initial start-up to allow
engine and generator to stabilize.
STOPPING ENGINE
•
Disconnect all electrical loads.
•
Turn OFF/RUN/START switch to "OFF" position.
OFF
RUN
MARCHE
ARRÊT
•
Close fuel shut-off valve.
IMPORTANT: Never store engine with fuel in tank,
indoors, or in enclosed, poorly ventilated areas or
where fuel fumes may reach an open flame.
RUN
START
DÉMARRAR
START
DÉMARRAR