Maintenance
The compressor should be checked
often for any visible problems and the
following maintenance procedures
should be performed each time the
compressor is used.
1. Pull ring on safety valve and allow it
to snap back to normal position.
WARNING
!
cannot be actuated or it leaks air after
ring is released.
or
Figure 8
ga
Notes
,
e
ón
ón
c-
on
ay
All manuals and user guides at all-guides.com
2. Place unit in the horizontal position
as shown in Figure 8. With
compressor shut off and pressure
released: Drain moisture from tank
by opening drain cock underneath
tank.
3. Turn power OFF and clean dust and
dirt from pump cover, tank and air
lines.
Safety valve must
IMPORTANT: Unit should be located as
be replaced if it
far from spraying area as hose will
allow to prevent over-spray from
clogging filter.
LUBRICATION
This is an oilless type compressor
requiring no lubrication.
STORAGE
1. When not in use, hose and compres-
sor should be stored in a cool dry
place.
2. Tank should be drained of moisture.
3. Hose should be disconnected and
hung open ends down, to allow any
moisture to drain.