ACESOL Classic Serie Manuel D'installation page 14

Émetteur thermique à haut rendement et basse consommation

Publicité

Les langues disponibles

Les langues disponibles

All manuals and user guides at all-guides.com
English
tions and those for each particular Country.
- The fixed connection should be made by a professional.
- These appliances must be earthed.
- There must be a thermal magnetic switch or other device that completely
disconnects the electricity supply from the appliance; this device must have a
separation of the contacts of at least 3 mm. at all the poles.
- When installing the radiator, make sure that the connecting cable can never be in
contact with a hot area of the appliance.
- Proceed with the connection to the mains circuit, making sure that the voltage is the
same as that shown on the appliance registration plate.
4. Controls.
The equipment consists of:
1. StandBy key.
Use to start, stop or block access.
2. Status LED.
Will indicate the situation according to status:
- LED solid red = Mode Stopped. (The equipment will not work under any
circumstances, although it continues feeding the network).
- LED green: Connected mode. (The equipment is connected, but the radi-
ator is not using energy).
- LED amber: Load mode. (The equipment is connected and heating)
3. Thermostat.
T o select ambient temperature in Comfort mode.
4 .Mode key.
Selects the work function. This function will be indicated according to
the status of the associated LED.
5. LED Mode.
Solid illumination
Flashing illumination = Economy mode
Off
5. Operation modes.
Comfort Mode: T
time the area is occupied, according to the position selected on the thermostat control.
Economy Mode: T
temperature 3.5 ºC below the temperature selected in the Comfort mode.
Anti-freeze Mode: T
below 7ºC, working only to avoid the temperature falling. This mechanism is especially
useful in places with low temperatures.
6. Start-Up and operation.
1. Press the StandBy key until the LED associated to it changes to green or amber.
2. Press the MODE key until the LED associated to it shines a solid colour
3. Turn the thermostat control clockwise to its limit (the status LED should be amber)
4. Once the room has reached the desired temperature, turn the thermostat control
anticlockwise slowly, until the status LED is green. From that moment, the device wil
switch on and off automatically, maintaining the selected ambient temperature
constant.
5. T o turn off the equipment, press the StandBy key. (LED status red) l
ACESOL
14
(Fig. 9)
he transmitter will keep the ambient temperature constant for the
he transmitter will automatically maintain an ambient
he transmitter will not work unless the ambient temperature falls
Classic
- Installation manual - Instructions for use
= Comfort mode
= Anti-freeze mode
EN