Télécharger Imprimer la page

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

INSTALLATION &
OWNER'S MANUAL
8175 W. Buckeye Rd., Phoenix, AZ 85043
Toll Free: 1.800.621.5886 • Fax: 480.753.3397
Paramount@1Paramount.com • www.1Paramount.com
US and Foreign patents and patents pending see www.1paramount.com/support/patent-numbers/
Paramount products are designed by Paramount in Phoenix, Arizona, United States of America
004-027-8703-00 R03 ECN_2364
PUB10262022 ©2022 Hayward Industries, Inc.

Publicité

loading

Sommaire des Matières pour Paramount EDC 004-152-4516-00

  • Page 1 8175 W. Buckeye Rd., Phoenix, AZ 85043 Toll Free: 1.800.621.5886 • Fax: 480.753.3397 Paramount@1Paramount.com • www.1Paramount.com US and Foreign patents and patents pending see www.1paramount.com/support/patent-numbers/ Paramount products are designed by Paramount in Phoenix, Arizona, United States of America 004-027-8703-00 R03 ECN_2364 PUB10262022 ©2022 Hayward Industries, Inc.
  • Page 2 Table Of Contents Installing The Canister ....................6 Plumbing The Canister ....................7 Plumbing Before The Equipment Header Or Pump ..........7 Plumbing After The Suction Side Header And Before The Pump..... 8 Pressure Testing ......................9 Home Owner Instructions: Cleaning The Basket ..........10 Winterizing The EDC Canister ................11 Head Loss Curve .......................12 Basic Dimension Drawing ..................12...
  • Page 3 Signal Words and Symbols Used In This Manual This Owner’s Manual and Installation Guide contains specific precautions and symbols to identify safety-related information. You will find DANGER, CAUTION, WARNING, NOTICE and SAFETY INSTRUCTIONS symbols which require special attention. Please read them carefully and follow these precautions as indicated! They will explain how to avoid hazards that may endanger you or persons using or maintaining your pool or spa.
  • Page 4 Fully secure lid assembly to canister before applying pressure. If lid isn’t fully secured it will DANGER result in serious injury or death. Do not remove this lid when this canister is under pressure. Removing this lid with the DANGER canister under pressure will result in serious injury or death.
  • Page 5 Clear lid & bayonet assembly The inlet port is 2½" 2 ports for schedule 40 plumbing in the pipe size on optional Clear the ID. The OD O3 ozone water accepts a 3" purifi er or vacuum coupler (spigot) gauge The outlet port is 2½"...
  • Page 6 LOCATING THE CANISTER FOR BELOW GRADE INSTALLATION The EDC canister can be installed below grade. The minimum hole footprint is 24" x 24". The hold depth varies for per your requirements. Backfi ll the hole after plumbing; be sure to compact the soil around the canister to ensure stability. 2½"...
  • Page 7 PLUMBING THE EQUIPMENT SIDE CANISTER This debris canister should only be installed WARNING on the suction side of the system. Pump Pump Filter Filter Isolated Suction Port 8" Minimum 8" Minimum Straight Pipe Straight Pipe Other Suction Header Items All Suction Header OPTION 1: OPTION 2: ALL SUCTION PIPES...
  • Page 8 Apply primer twice before gluing pipe or fittings to EDC canister Install 3-way valve ahead of the EDC ONLY 8" minimum straight pipe pump Suction from the skimmer, main drain or spa Always be sure to have a minimum of 8 NOTICE inches of pipe between the suction inlet of the pump and the fi rst connection whether...
  • Page 9 The ¼" NPT ports can be used for a pressure gauge during pressure testing or a vacuum gauge during normal operation. Another use would be for a suction side device such as the Paramount Clear03 ozone generator. The single ½" pipe ¾" fitting port can also be used for suction side devices.
  • Page 10 HOME OWNER INSTRUCTIONS: CLEANING THE BASKET Fine mesh basket Debris basket Ring Make sure to turn off the pump. The lid NOTICE cannot be removed from the ring. To clean the basket you must remove the lid. Turn the two handles counter- clockwise one quarter turn.
  • Page 11 When replacing the lid and ring make sure that the top of the EDC canister is free from all dirt and debris and the o-ring on the lid is clean. Paramount does not recommend using lube on the lid o-ring as it attracts dirt and debris. Some lubricants can cause swelling and damage to the o-ring.
  • Page 12 Paramount Part# Description 004-152-4516-00 EDC Canister Complete 005-152-2205-00 Lid Assembly includes, clear lid, ring, o-ring 005-152-2206-00 O-Ring 005-152-2207-00 Basket Assembly 005-152-2208-00 Canister Replacement body only 004-152-4517-00 Optional Fine Mesh Bag...
  • Page 13 8175 W. Buckeye Rd., Phoenix, AZ 85043 Toll Free: 1.800.621.5886 • Fax: 480.753.3397 Paramount@1Paramount.com • www.1Paramount.com US and Foreign patents and patents pending see www.1paramount.com/support/patent-numbers/ Paramount products are designed by Paramount in Phoenix, Arizona, United States of America 004-027-8703-00 R03 ECN_2364 PUB10262022 ©2022 Hayward Industries, Inc.
  • Page 14 Table des matières Installer La Boîte Filtrante ..................18 Bien Fixer L’unité Au Socle ..................18 Tuyauterie De La Boîte Filtrante ................19 Tuyauterie Avant Le Port De L’appareil Ou La Pompe ........19 Tuyauterie Après L’extrémité Aspirate Et Avant La Pompe ........20 Essai De Pression .......................21 Consignes À...
  • Page 15 MOTS ET SYMBOLES UTILISÉS DANS LE PRÉSENT GUIDE La présent manuel du propriétaire et guide d’installation contient des précautions et des symboles spécifiques visant à vous transmettre des renseignements sur la sécurité. Les symboles et les mots DANGER, PRÉCAUTION, AVERTISSEMENT, et RENSEIGNEMENT DE SÉCURITÉ doivent faire l’objet d’une attention particulière.
  • Page 16 Ne pas enlever ce couvercle lorsque la boîte filtrante est sous pression, au risque de vous DANGER exposer à un risque de lésion physique grave ou mortelle. Ne pas se tenir au-dessus du couvercle lorsque la boîte filtrante est sous pression, au risque de DANGER vous exposer à...
  • Page 17 Couvercle transparent et ensemble de raccord à baïonnette L’orifi ce d’admission Ports pour la est un tube de tuyauterie du 2½" de DI et purifi cateur d’eau de calibre 40. (facultatif) Clear O3 Le DE peut ozone, ou le tuyau être relié...
  • Page 18 INSTALLER LA BOÎTE FILTRANTE SOUS LE NIVEAU DU SOL La boîte fi ltrante peut être installée sous le niveau du sol. Creuser un trou d’au moins 24” x 24”/61 cm x 61 cm, sans restriction de profondeur. Remblayer le trou après y avoir installé la tuyauterie, en veillant à bien tasser le sol autour de la boîte fi ltrante afi n d’en assurer la stabilité.
  • Page 19 TUYAUTERIE DE LA BOÎTE FILTRANTE Cette boîte de filtration des débris ne doit être installée qu’à l’extrémité d’aspiration du AVERTISSEMENT système. Pump Pump Filter Filter Tuyau d’u Moins 8 po. l'orifice d'aspiration isolé Tuyau d’u Moins 8 po. Autre aspiration header article Tous aspiration Header OPTION 1:...
  • Page 20 Installez la valve à 3 voies en amont SEULEMENT du EDC Tuyau d’u Moins 8 po. Pump La succion du récupérateur, du drain principal et du spa Veiller à toujours laisser au moins 8 po./20 AVIS cm de conduite entre l’entrée aspirante de la pompe et le premier raccord, qu’il s’agisse d’un EDC ou d’une manivelle de plomberie.
  • Page 21 Vous pouvez aussi utiliser un manomètre à vide pendant le fonctionnement normal, ou un appareil d’aspiration latéral comme le générateur d’ozone Paramount Clear03. Le port de fixation de ¾" pour conduite de ½" peut aussi être utilisé pour les appareils d’aspiration latéraux.
  • Page 22 Avant de remettre le couvercle et l’anneau, assurez-vous que la partie supérieure de la boîte filtrante EDC soit sans saletés ni débris, et que l’anneau circulaire soit propre. Paramount ne recommande pas l’utilisation de lubrifiants sur l’anneau circulaire du couvercle, puisqu’ils accumulent la saleté et les débris, et que certains font gonfler et endommagent l’anneau circulaire.
  • Page 23 PRÉCAUTION : Un sac fileté facultatif est disponible pour les débris fins qui pourraient passer par le panier standard. Son utilisation exige des nettoyages plus fréquents. HIVÉRISATION DE LA BOÎTE FILTRANTE EDC Pour les zones sujettes au gel, le bidon EDC doit être hiverné. Pour hiverner, enlevez le couvercle du bidon et le couvercle de la pompe.
  • Page 24 Pièce Paramount Description 004-152-4516-00 Boîte filtrante EDC Complete Ensemble-couvercle, avec couvercle transparent, pince de fixation de 005-152-2205-00 type baïonnette et anneau circulaire 005-152-2206-00 Anneau circulaire 005-152-2207-00 Ensemble panier 005-152-2208-00 Pièce principale de remplacement pour la boîte filtrante 004-152-4517-00 Sac fileté facultatif...