2.
If necessary, add a premium quality, 30-weight, non-detergent oil into the Oil Fill
Hole until the level of oil reaches the maximum level as indicated on the Oil Win-
dow (20B). The optimal capacity of the oil reservoir is 30 ounces. Do not overfill.
Then thread the Dip Stick back into the Oil Fill Hole, being careful not to strip the
plastic threads.
front Cover (18b)
oil Window (20b)
To Turn The Air Compressor On:
1.
Check to make sure the Water Drain Valve (10A) is fully closed.
2.
Turn the Air Flow Valve (6A) to its "OFF" position.
3.
Connect the air hose (not provided) to the Air Flow Valve (6A) of the Air Com-
pressor. Then, connect the other end of the air hose to the pneumatic tool (not
provided) that is to be used.
4.
note: always plug the Power Cord of the air Compressor into a 115 V~
electrical source (±10% maximum variation).
5.
Rotate the "ON/OFF" Power Switch (1A) to the horizontal position to turn the Air
Compressor on. (Rotate the "ON/OFF" Power Switch (1A) to the vertical position
to turn the Air Compressor off.)
6.
Allow sufficient time for the Tank Pressure Gauge (4A) to indicate 80 PsI before
using the Air Compressor.
7.
Turn the Air Flow Valve (6A) to its "ON" position to allow air to the pneumatic tool.
SKU 94667
for technical questions, please call 1-800-444-3353.
(see figure C, and assy. diagram b.)
dip stick (14b)
fIGurE C
English
PAGE 6