IMPIANTO ELETTRICO - ELECTRICAL SYSTEM - SYSTÈME ÉLECTRIQUE - ELEKTRISCHE ANLAGE -
INSTALACIÓN ELÉCTRICA - ЭЛЕКТРИЧЕСКАЯ СИСТЕМА - ΗΛΕΚΤΡΙΚΗ ΜΟΝΑΔΑ -
A - MAIN POWER SUPPLY (can be ordered as come optional)
Install in the safety zone: Z3
Input: 100-240 V ac, 50÷60 Hz
Output: 12 V dc, 4,5 A (max)
Standard: IEC60950-1
Safety: SELV Class II
B - CONTROL SYSTEM
Install in the safety zone: Z1-Z2-Z3
Protection class: IP66
C - ANCILLARY LINE POWER SUPPLY (order as optional)
Install in the safety zone: Z3
Input: 100-240 V ac, 50÷60 Hz
Output: 12 V dc, 4,5 A (max)
Standard: IEC60950-1
Safety: SELV Class II
D - TRACK
Protection class: IP67
E - REMOTE CONTROL
Install in the safety zone: Z1-Z2-Z3
Protection class: IP66
Battery: CR2032
F - POWER SUPPLY/CONTROL UNIT PER SENSOR PIR (can be ordered as optional)
Install in the safety zone: Z3
Power: < 1 W
Input: 230 V ac
Safety: IP20 / II / CE
Service temperature: -25°C÷50°C
G - PRESENCE SENSOR "PIR" (can be ordered as come optional)
Install in the safety zone: Z1-Z2-Z3
Safety: IP65 / II / CE
Service temperature: 0°C÷45°C
H - ELECTRICAL FILTER
Install in the safety zone: Z3
Service temperature: -10°C÷40°C
Connection between A-B
Length max = 8 m
Poles = 2
Section = 20-22 AWG
Connection between C-D
Length max = 8 m
Poles = 2
Section = 20-22 AWG
Cable diameter: 4÷6 mm (PG7)
Connection between B-D
Length max = 8 m
Poles = 4
Section = 20-22 AWG
Cable diameter: 4÷6 mm (PG7)
Connection between F-B
Length max = 10 m
Poles = 2
Section = 20-22 AWG
Cable diameter: 4÷6 mm (PG7)
Connection between H-A
Length max = 1 m
Poles = 2
Section = 18 AWG
WARNING:
- the connection to a cut out switch with intervention current not greater than 30mA is mandatory.
- on the supply cable "L+N" (not included), to guarantee compliance with the requirements of Electromagnetic
Compatibility, it is necessary to position the following ferrite: Trademark: Fair-Rite Products Corp - Model: 431164281
or a component with similar characteristics.
All manuals and user guides at all-guides.com
DATA FOR THE ELECTRICAL SYSTEM
ELECTRICAL CONNECTIONS DATA
19