6) Snap on LED board carrier by aligning screws in LED board carrier with notches in housing. Then pivot board
carrier until opposite side snaps in as shown in Fig 2.
FIGURE 2: BOARD CARRIER
FIGURE 4
B. With the sides of the lens pressed
inward at one end, shift the entire
lens toward the same end as shown.
(See Figure 4)
8) Reverse this complete process to remove lens.
CAUTION:
This fixture is designed for permanent installation in ordinary (Non-Hazardous) locations in accordance with the National Electrical Code and
all applicable local codes. Do not use in areas of limited ventilation or in high ambient enclosures. The lamp and fixture operate at high temperatures.
Contact with combustible materials can cause fire and personal contact can cause severe burns.
Signify North America Corporation
200 Franklin Square Drive
Somerset, NJ 08873
Phone: 855-486-2216
CAUTION: THE INSTALLATION AND SERVICING OF
THIS PRODUCT SHOULD BE PERFORMED BY A
QUALIFIED ELECTRICIAN OR SERVICE PERSONNEL
7) Lens Installation
A. At one end of the lens
press inward as shown
to clear retainer tabs.
(See Figure 3)
SHIFT THE LENS
TO ONE END.
C. Once the lens has been shifted
to one end, the opposite end will
be able to side into the end cap, center lens
on fixture once installed.
Signify Canada Ltd. / Signify Canada Lte
281 Hillmount Road
Markham ON, Canada L6C 2S3
Phone: 800-668-9008
PRESS INWARD
FIGURE 3: LENS
PRESS INWARD
FIGURE 5
(See Figure 5)
12NC: 442100317150
DB100425 4/21/2021
RETAINER TABS
(ENGLISH)