EDITING THE UNDER SETTING
1. The display shows
SEt.LO.
YES button to edit setting.
Settings:
-999950 to 999950
Refer to Menu Navigation
to enter settings.
NOTE: The minus sign is used
together with the first digit to
show a negative value.
EDITING THE OVER SETTING
1. The display shows
SEt.HI.
YES button to edit setting.
Settings:
-999950 to 999950
Refer to Menu Navigation
to enter settings.
BEGIN CHECK WEIGHING
The appropriate under, accept or over
LED lights indicate check weigh status.
1.
Place a sample on the scale and
read the weight.
2. For loads less than the under limit,
the yellow under LED is lit.
3. For loads greater than the under
limit and less than the over limit, the
green accept LED is lit.
4. For loads greater than the over
limit, the red over LED is lit.
DYNAMIC WEIGHING
Use this mode to weigh moving or
oversized objects. The weight is held
on the display until reset. Manual,
semi-automatic and automatic start/stop methods are
available.
BEGIN DYNAMIC WEIGHING
1.
When the display shows
place the object on the scale.
2. If the manual mode is in use, press
the FUNCTION MODE button to start measurement.
If the semi-automatic or automatic mode is in use,
measurement is started automatically.
PAGE 8 OF 32
All manuals and user guides at all-guides.com
OPERATION CONTINUED
Press the
SEt.LO
to
Press the
SEt.HI
 . O.000
. O.123
. 1 1 1.234
. 122.345
dYNA
,
rEAdY
rEAdY
NOTE: When using manual
mode, it is not necessary
for the display to be at zero
kg
gross or net. When using
semi-automatic or automatic
mode, the display must be
at zero gross or net before
kg
placing the object on the
scale. The example is for a
setting of five seconds. During
the averaging period, the
kg
countdown timer decreases
in one second increments.
NOTE: If SEt 0 was selected in the dynamic menu
item, the countdown timer is not displayed.
kg
3. When the countdown has
completed, the readings are
averaged and held on the display.
The averaged weight is displayed
kg
until rest.
4. If the manual or semi-automatic
mode is in use, reset the countdown
timer by pressing the FUNCTION
MODE button. Then the display
kg
shows
rEAdY
5. If the automatic mode is in use,
the held reading is shown on the
display for 10 seconds after the
kg
object is removed to within five
divisions of zero. Then, the display shows
6. The scale is now ready to accept a new object.
LEGAL FOR TRADE
kg
When the indicator is used in trade or a legally
controlled application, it must be set up, verified and
sealed in accordance with local weights and measures
regulations. It is the responsibility of the purchaser to
kg
ensure that all pertinent legal requirements are met.
SETTINGS
Before verification and sealing, perform the following steps:
kg
1. Verify that the menu settings meet the local weights
and measures regulations.
2. Perform a calibration.
3. Set Legal for Trade to ON in the setup menu.
4. Without exiting the menu, turn the indicator off.
5. Disconnect power from the indicator and open the
housing.
6. Set the security switch to ON.
7. Close the housing.
8. Reconnect power and turn the indicator on.
.
5 SEC
1 SEC
. 1.234
kg
~
. 1.234
kg
~
rEAdY
.
rEAdY
0521 IH-2289