This measuring accuracy applies for temperatures from 18 °C to 28 °C and a
relative air humidity less than 80 %.
7.1 DC voltage ranges
The input resistance is 10 MΩ.
Measuring
Resolution
range
200 V
600 V
7.2 AC voltage ranges
The input resistance is 10 MΩ in parallel 100 pF.
Measuring
Resolution
range
200 V
600 V
7.3 AC current ranges
Measuring
Resolution
range
40 A
0.1 A
200 A
0,1 A
400 A
The measured value is obtained by mean value rectification and is displayed
*1
as r.m.s. value. Its calibration is adapted to a sinusoidal curve.
The stated accuracy is specified for conductors that are centrally clamped
by means of the current clamp L (see figure 4 AC current measurement).
For conductors that are not centrally clamped, an additional error of 1 % of
the displayed value has to be considered.
7.4 Resistance measuring range and acoustic continuity test
Overload protection: 600 V
Measuring
Resolution
range
200 Ω
0.1 Ω
2 kΩ
1 Ω
20 kΩ
10 Ω
200 kΩ
100 Ω
2 MΩ
1 kΩ
20 MΩ
10 kΩ
The integrated buzzer sounds if the resistance R is lower than 20 Ω.
The change-over point of the range selection might be already at a value of
1400!
8.
Measuring by means of the TESTFOX CC
8.1 Preparing the measurement
Operate and store the TESTFOX CC at the specified storage and operating
temperatures only! Do not permanently expose the device to sunlight.
-
Check stated nominal voltage and nominal current on the safety measuring
lines. Nominal voltage and current of the enclosed safety measuring lines
comply with the respective values of the TESTFOX CC.
-
Check insulation of the safety measuring lines. If the insulation is damaged,
the safety measuring lines must be replaced immediately.
-
Check the safety measuring lines for continuity. If the conductor in the
safety measuring line is interrupted, replace the safety measuring lines
immediately.
-
Before selecting another function by means of the sliding switch 7,
disconnect the safety measuring lines from the measuring point.
-
Strong sources of interference in the vicinity of the TESTFOX CC might
involve unstable readings and measuring errors.
10/ 2008
0.1 V
± (1.0 % of the measured value + 2 digits)
1 V
± (1.0 % of the measured value + 2 digits)
Measuring accuracy
0.1 V
± (1.5 % of the measured value + 5 digits)
1 V
± (1.5 % of the measured value + 5 digits)
Measuring accuracy
the frequency range 50 Hz - 60 Hz
± (1.9 % of the measured value + 10 digits)
± (1.9 % of the measured value + 5 digits)
1 A
± (1.9 % of the measured value + 5 digits)
eff
± (1,0 % of the measured value + 5 digits)
± (0.7 % of the measured value + 2 digits)
± (0.7 % of the measured value + 2 digits)
± (0.7 % of the measured value + 2 digits)
± (1.0 % of the measured value + 2 digits)
± (1.9 % of the measured value + 5 digits)
TESTFOX CC
Measuring accuracy
within the frequency
*1
range 50 Hz - 500 Hz
*1
Measuring accuracy
protection
within
protection
Max. open-
circuit voltage
Overload
600 V
eff
600 V
eff
Overload
protection
600 V
eff
600 V
eff
Overload
600 A
eff
600 A
eff
600 A
eff
1.3 V
1.3 V
1.3 V
1.3 V
1.3 V
1.3 V
11