Line laser
Checking precision
Caution!
The power tool may be adjusted
by authorised technicians only.
Requirement for exact check:
– 2 parallel walls, distance approx. 10 m,
– Height-adjustable tripod, etc. .
n Place the machine on the tripod in front
of wall A and adjust with the aid of the
spirit level (3).
– The bubble deviation of the spirit level
should be as low as possible after
a 180° rotation.
n Switch on "laser point" operating mode.
– Mark laser point A1 on wall A
All manuals and user guides at all-guides.com
.
n Rotate the machine by 180° and mark
laser point B on wall B
n Place the machine in front of wall B and
align in such a way that the laser point
corresponds exactly with mark B.
n Rotate the machine by 180° and mark
laser point A2 on wall A
.
n Determine the vertical distance between
points A1 and A2.
– Maximum deviation: 6 mm/10 m
Maintenance and care
Cleaning
If the power tool is damp after use, wipe the
power tool and accessories with a dry, soft
cloth.
Do not use solvents or abrasive cleaning
agents to remove dirt. Use a clean cloth
moistened with water and a mild detergent.
Remove dust, etc. from the laser head (5)
with a soft cloth.
Repairs
Repairs may be carried out by an authorised
customer service centre only.
Accessories
Spare-part/Accessory
Clamping column
Elevator tripod, medium-sized
(0.65–2.00 m)
Elevator tripod, large
(0.90–2.85 m)
.
Order
no.
312.096
312.118
312.126
13