Groupes Electrogènes FP 1000 Inverter et FP 2000 Inverter
spouting pump.
I. Turn the switch of the engine to the "CLOSE" position. Then screw the oil-
discharging screw tightly.
J. Re-install the cap of the spark plug on the spark plug.
3. Discharge the machine oil.
4. Dismantle the spark plug, and pour a big spoon of clean machine oil into the
engine. Make the engine rotate for several circles to make the oil evenly
distribute. Install the spark plug again.
5. Pull the starting hold (Fig. 2) slowly until you feel the resistance. At this time,
the piston reaches the compressed stroke, and both the entering and the
discharging valve are closed. To store the generator under such condition will
help to prevent the inside of the machine rusting.
62