S-10759, S-14365
S-16914, S-19415
CLOSED TOP STEEL DRUMS
Pursuant to the requirements of the Department of Transportation in CFR 49 Part 178.2(c)(1), this method of closure
should be used to ensure that your containers have been closed in the same manner as when they were
initially tested.
PLUG CLOSURE INSTRUCTIONS
1.
Place the plugs into the appropriate bung.
2. Turn the plug gently clockwise, ensuring that the plug enters the bung properly.
3. Using a torque wrench, tighten the plug according to the manufacturer's recommended torque below.
TORQUE SPECIFICATIONS
NOTE: Uline does not ship containers to customers with closures secured to compliance specifications. It
is the responsibility of the individual who fills the container to ensure the container is in UN compliance
before shipping. Contact Uline with questions regarding proper closing methods.
CAUTION! Use only the plugs and gaskets supplied with the drums. Insert and tighten all plugs into their
appropriate threaded flanges until snug. Using a torque wrench, tighten each fitting to the correct torque.
Torque is based on the manufacturer's closure recommendations. Drums closed in this manner meet the
UN performance-oriented packaging standards test requirements for the container markings shipped.
CAUTION! After filling and prior to transport, the shipper should check the closures to determine if closures
need to be tightened due to heating, cooling or gasket relaxation.
SIZE AND FITTING STYLE
AMERICAN FLANGE – 2" STEEL – EPDM GASKET
AMERICAN FLANGE – 3/4" STEEL – EPDM GASKET
PAGE 1 OF 3