Programming with MTMA/01 MTMV/01 modules in SLAVE mode
Programming relay codes with badges
Door release code programming associates badges with the relays present on the MTMA/01 MTMV/01 module. Control is local and if
you have multiple MTMA/01 MTMV/01 modules, you need to program the door release codes on each entry panel.
N.B. The procedure for programming the door release and relay codes erases all previously programmed codes.
PROG
PROG
>3''
A
A
❶
ON
1
2
3
4
SW4
C
PROG
PROG
<1''
A
D
VA/01
SW2
SLAVE
M1
B
ON
1
2
3
4
SW4
❷
❸
beep
Exiting programming
Briefly press the PROG key D: the entry panel indicator LEDS go off.
M1
Accessing programming
With VA/01: press PROG A until the
PROG LED lights up.
Without VA/01: press PROG B on the
entry panel for at least 3 seconds and re-
lease within 6 seconds.
PROG
PROG
Use the dip switches on SWITCH SW4 to set the relay with which
to associate the badge C❶:
associate the badge with the first VLS/2 relay
associate the badge with the second VLS/2 relay
associate the badge with the auxiliary contact on the
MTMA/01 MTMV/01 module
associate the badge with the door release control on
the MTMA/01 MTMV/01 module
Swipe the badge on the entry panel you wish to program C❷.
A tone will confirm that the association has taken place C❸; 3
quick tones will indicate an error condition.