Safety and operating instructions
Tightening torques
TEX 09PS
B
F
E
C
TEX 10PS
20
A
C
D
© 2013 Atlas Copco Construction Tools AB | No. 9800 1386 90 | 2013-04-15
A
TEX 12PS
Air inlet nipple, use Loctite® 243™ (Loctite is
A.
a registered trademark of Henkel Corporation.
243 is a trademark of Henkel Corporation.)
Handle, 450 Nm for TEX 10PS
B.
C.
Nut, 70 Nm
Bushing, use Loctite® 603™ (Loctite is a
D.
registered trademark of Henkel Corporation.
603 is a trademark of Henkel Corporation.)
Nut, 350 Nm
E.
F.
Air inlet nipple, 300-350 Nm. use Loctite®
243™.
Troubleshooting
If the pneumatic machine does not start, has low
power or uneven performance, check the following
points.
♦
Check that the insertion tool being used has the
correct shank dimension.
♦
Check that the pneumatic machine is getting the
correct amount of lubricant. Too much lubrication
can cause starting problems, low power or uneven
performance.
♦
Check that the compressed air system supplies
the machine with sufficient air pressure to give full
power.
♦
Check that the dimension and length of the air
hose are according to the recommendations. See
"Installation".
TEX 09PS, 10PS, 12PS
C
Original instructions