TROUBLESHOOTING
1. The pump does not turn on:
Check the power supply connection
2. The pump turns on but does not function:
Check display and configuration: the pump could be disabled or an alarm is active
3. The pump works correctly but does not inject liquid into the plant:
Check the level of product in the tank
Check that the foot filter is not clogged
Check that the injection valve is not clogged
Check the suction and head valves
4. Liquid leakages from pump body:
Check that the tubes are well inserted and the nuts well tightened
Check that the pressure at the injection point is not too high
Remove the transparent protection cover and check the integrity of the internal tube
| BL220 PERISTALTIC PUMPS
14
All manuals and user guides at all-guides.com
Before turning off the system at the end of the season or for a long
period, dose cleanwater to rinse the tube, then place the roller-holder as
shown in the figure, rotating it clockwise.