CLEANING & MAINTENANCE
Cleaning of the machine
This can be done with non-aggressive and non-abrasive cleaning products.
Fast coupling maintenance
The O-ring in the fast coupling will age due to the influence of the cleaning liquids and mechanical stress
by the coupling action.
The machine contains on spare set of O-rings for replacement. O-rings can easily be replaced by uns-
crewing the two coupling parts.
DETECT FAILURES
ACTION
FAILURE
Connect the return
Pump does not start
hose to the engine.
to run.
Fill the tank with
liquid.
Open the pressure
regulator completely
(turn counter –
clockwise).
Press the START
button.
Tank is empty, pump
start to work.
When pouring liquid
in the tank, the
pump starts running.
Engine is running but
pump does not
generate any
pressure.
POSSIBLE CAUSE
SOLUTION
Loose contacts at :
Fix the again.
- Floating device
- Pump
Electronic card is
Replace the card
faulty
Fuse has melted
Replace the fuse
Pump is faulty
Replace the pump
The floating device
Replace the floating
does not make
device by a new one
contact.
Electronic card is
Replace
faulty.
Floating device is
Replace
faulty.
Press the STOP
Overpressure in
system.
button. Attend the
stop the motor. Turn
pressure regulator
completely open.
Press the START
button.
DETECT FAILURES
ACTION
FAILURE
Slowly close the
The pressure
pressure regulator to
increases irregularly.
increase the
pressure.
The pressure
increases
insufficiently or not at
all.
With regulator open,
the initial pressure is
too high.
For carburettor
Pression does not
engines: turn
sufficiently drop.
pressure regulator
completely counter-
clockwise
POSSIBLE CAUSE
SOLUTION
Pump is damaged.
Replace the pump.
Pressure gauge is
Replace the pressure
damaged.
gauge.
Regulator is
Replace the
damaged.
regulator.
Regulator leaks
Dismount it and
Resistance in
replace the seals.
pressure hose
Open the machine
because of a crack in
and replace the hose.
the between pressure
gauge and outside
pressure connection.
Resistance in the
regulator.
Dismount it, check it
Regulator is
and eventually repair
damaged.
or replace it.
Crack in the hose at
regulator inlet or
Replace the hose if
outlet.
necessary.
Obstruction in
Repair or replace.
pressure regulator or
in valve.
Damaged seals.
Replace them.
Too high a pressure
Use carburettor
inside carburettor.
adapter.