2A/30VDC (Resistive load)
2A/250VAC (Resistive load)
Temperature Measurement Accuracy: 0,1°C
Operating Sensitivity: 0,5°C
Operating Temperature Range: 5°÷30°C
Battery Life: 1 Year (2 x AAA)
Operating Temperature: -10°÷50°C
Storage Temperature: -20°÷°C
CONTROLS AND DISPLAY LEGEND
1
Ba.ery Indicator
2
Room Temperature
3
Set Temperature
4
Cooling Indicator
- If the Cooling Indicator is blinking, the cooling unit is working.
- If the Cooling Indicator is steady, the cooling unit is not working.
5
HeaRng Indicator
- If the HeaRng Indicator is blinking, the heaRng unit is working.
- If the HeaRng Indicator is steady, the heaRng unit is not working.
6
ON/OFF and Temperature SeSng Bu.on
INSTALLATION
ROOM THERMOSTAT PLACEMENT
Room Thermostat needs to be placed in the room which is used most frequently. For
instance; living room or lounge. Placing the Room Thermostat in a spot that have air
circulation like entrance of a room or side of window should be avoided. Also anywhere
close to heating/cooling units such as radiator, stove and spots which get direct sun
lights would not be suitable. Room Thermostat needs to be located above the floor 150
cm height. Few trials may be made to find the most convenient spot.
Warning! It is recommended to install the thermostat scrupulously complying with the
safety standards and legal provisions in force. Before making any connections, make
sure that the main switch has been turned off.