Ducting Requirements - Samsung DV22K6800 Série Mode D'emploi

Sèche-linge
Masquer les pouces Voir aussi pour DV22K6800 Série:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Before installation

Ducting requirements

Weather hood
type
No. of 90°
elbows
0
1
2
3
NOTE
* Use a 4-inch (10.2 cm) diameter rigid aluminum or galvanized steel duct.
If you integrate the dryer's vent system with an existing exhaust system:
• Make sure the exhaust system meets all applicable local, state, and national regulations.
• Verify you are not using flexible plastic duct.
• Make sure to check for and remove all lint buildup from inside the existing ducts.
• Confirm the duct is not kinked or crushed.
• Make sure the exhaust hood damper opens and closes freely.
Manometer measurements
The static pressure in any exhaust system must not exceed 0.83 inches of water column
or be less than 0. Note that these values are measured with the dryer running with a
manometer presented to the exhaust duct that connects to the dryer. The dryer tumbler
must be empty and lint filter clean.
12
English
Recommended
4" (10.2 cm)
Rigid
80 ft. (24.2 m)
40 ft. (12.2 m)
60 ft. (28.3 m)
35 ft. (10.7 m)
45 ft. (13.7 m)
25 ft. (7.6 m)
35 ft. (10.7 m)
20 ft. (6.1 m)
Use only for short-run installation
Metallic
Rigid
flexible*
60 ft. (28.3 m)
45 ft. (13.7 m)
35 ft. (10.7 m)
25 ft. (7.6 m)
2.5" (6.4 cm)
Metallic
flexible*
30 ft. (9.1 m)
22 ft. (6.7 m)
17 ft. (5.2 m)
12 ft. (3.7 m)

Publicité

Table des Matières
loading

Table des Matières