Connecto
Installation Instructions
Single parts
Connecto
1
2
3
4
5
6
7
8
Connecting/terminating the heating cable
Connecto is used exclusively for the following
heating cables with protective braiding:
SLPG-10, SLPG-25, SLPG-33, SLIG-18, SLHW-45,
SLHW-55, SLHW-70
Technical datas
Electrical connection: max. AC 250 V, max. 16 A
Ambient temperature: max. +80 °C switched on
max. +100 °C switched off
(1.000 hrs cumulative)
min.
Danfoss GmbH
Postfach 100453
Bereich Wärmeautomatik
63004 Offenbach
A
1
1
1
1
1
-25 °C
Carl-Legien-Str. 8
63073 Offenbach
E
AE
V
1
1
2
1
2
1
2
1
2
1
1
1
Note
Only those heating cable with protective braiding as specified
above may be used. Each heating circuit must be incorporated
into a circuit which offers personal protection.
A double pole RCD with 30 mA trip should be used for a
maximum length of 500 m per heating cable. An automatic
fuse 16 A with C-characteristic is also required.
Observe the maximum heating circuit length for each type of
heating cable. Comply with Danfoss's general mounting
instructions. Connecto must be secured firmly. Ensure that
the connection cable is not subject to any pull, push or twisting
movements, e. g. by using cable ties.
The connection to the mains power supply must be
made by a qualified electrician.
When using roof gutter heating, the Connecto must be placed
outside the gutter, in the protected area, e.g. under the roof
overhang or under the gutter.