Troubleshooting
PROBLEM
1. Motor does
not run
2. Motor makes
muffled humming
sound
3. Motor is running,
but sprayer will not
spray
4. Stain or paint is
spitting
5. Excessive
overspray (fogging)
6. Uneven spray
pattern
www.homeright.com
C820425D.f_MAN_Pro50-55_EN-FR-ES.indd 15
CAUSE
A. No power to motor.
B. Loose electrical connection.
C. Defective motor or switch.
A. The volume control knob is screwed in all the way.
B. Seized piston.
C. Plugged atomizer valve or spray tip.
D. Atomizer valve assembly is not seated properly.
A. Seized piston.
B. Atomizer valve plugged.
C. Atomizer valve not properly seated.
D. Stain or paint material is too thick.
E. Pick-up tube is not tight to cylinder housing.
F. Spray tip clogged.
G. Worn piston.
A. Container volume is low.
B. Improper adjustment.
C. Stain or paint material is too thick.
D. Pick-up tube is not tight to cylinder housing.
E. Loose spray tip.
F. Stain or paint material has impurities.
G. Worn piston/cylinder.
H. Worn atomizer valve.
I. Plugged atomized valve/
A. Sprayer too far from surface.
B. Pressure too high.
C. Worn spray tip.
D. Stain or paint material is too thick.
A. One or more holes in the atomizer valve are clogged.
B. Partial blockage in spray tip.
C. Worn atomizer valve.
D. Worn spray tip.
REMEDY
A. Check wall outlet and extension cord.
B. Discontinue use. Call Customer Service.
C. Call Customer Service.
A. Adjust the volume control knob.
B. Remove piston and cylinder housing and clean. (See pg 13,
steps 7-8) Then add petroleum oil to metal shaft of piston.
C. Replace atomizer valve and clean holes in spray tip.
D. Replace atomizer valve.
A. Remove piston and cylinder housing and clean. (See pg 13,
steps 7-8) Then add petroleum oil to metal shaft of piston.
B. Ensure that atomizer valve is clean and free from debris.
C. Ensure that the atomizer valve is properly seated in the
cylinder housing. Also, check to make sure the atomizer
valve is inserted correctly.
D. Thin stain/paint according to manufacturer's requirements.
We recommend thinning 5-8%.
E. Reattach pick-up tube to cylinder housing.
F. Thoroughly clean or replace spray tip.
G. Replace piston. Call Customer Service.
A. Refill container.
B. Adjust volume control knob. (See pg 9, steps 1-2)
C. Thin according to stain/paint manufacturer's requirements.
We recommend thinning 5-8%.
D. Clean and firmly insert into intake opening on pump housing.
(See pg 8, step 4)
E. Tighten spray tip.
F. Pour paint/stain material through strainer.
G. Replace piston. Call Customer Service.
H. Replace with new atomizer valve.
I. Clean and clear debris from three holes in atomizer valve.
A. Move sprayer closer to surface.
B. Adjust volume control knob.
C. Replace with new spray tip.
D. Thin according to manufacturer's requirements.
A. Clean three holes in atomizer valve.
B. Clean spray tip.
C. Replace with new atomizer valve.
D. Replace spray tip.