System Design - ITT AquaBoost AV 1.1 Installation, Programmation Et Utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

System Design

System Design
Note
Systems MUST be designed by qualifi ed technicians only and meet all applicable state and local
code requirements.
The following diagrams show a typical system using the AquaBoost Controller. Connection can be made directly to
a water supply or water can be drawn from a supply tank. Diagram #1 shows a typical set up for a supply tank.
Disconnect
Diagram 1
AquaBoost Installation
for Well Pump System
Diagram #2 shows a set-up for municipal water connection. This allows pump maintenance without main line
shut-off.
Diagram 2
AquaBoost Installation
for Municipal Water
System
A diaphragm pressure tank is used on the discharge side of the pump to maintain pressure in the line when
there is no demand. This will keep the pump from continuing to run. With the AquaBoost Controller, it is not
necessary to have a large tank for supply purposes. In selecting a tank, make sure it can withstand system pres-
sure. The tank should have a capacity of at least 10% of the maximum pump fl ow rate in gpm. Typically, pumps
used with the AquaBoost controller use a V6P or larger Goulds Pumps Hydro-Pro
the following:
PSI Set Pressure
15
PSI Tank Pre-charge 12
Home Supply
Circuit Breaker
AquaBoost Control
Gauge
Tank
Home Supply
Circuit Breaker
Disconnect
30
45
60
21
37
52
Check Valves
Isolation Valve
Unions
Relief
Valve
Check Valves
To Drain
AquaBoost Control
Relief
Gauge
Tank
Valve
To Drain
75
64
3
Atmospheric
Storage Tank
Water Main
Check Valves
Isolation Valve
Unions
Check Valves
®
Tank. Pre-charge the tank to
Well Supply

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Aquaboost av 1.15Aquaboost av 1.2

Table des Matières