Screw the flow reducer (17) to the G 3/8" water
supply pipe. Connect the flexible pipe with the G
1/2" cap to the fitting with flow reducer (17).
BLANCOLINUS-S-F ND
Screw the T-shaped fitting (19) to the G 3/8"
thread boiler outlet (colour red) making sure the
washer is positioned correctly. Screw the flexible
pipe of the shower head (7) to the T-shaped
fitting (19) placing the washer in the correct po-
sition. Connect the blue flexible pipe to the boiler
inlet (colour blue) and the red flexible pipe to the
T-shaped fitting (19).
BLANCOLINUS-F ND
Connect the blue flexible pipe to the boiler inlet
(colour blue) and the red flexible pipe to the boiler
inlet (colour red).
2
4
Connections
A.
Cold water inlet pipe
Heating boiler inlet pipe ( blue colour)
B.
C.
Hot water from heating boiler (red colour)
Functioning
Open the lever in hot water position and wait
for the water outlet, then join the battery to the
electricity. Switching on the battery ignition before
of the water refilling cause the fuse breaking inside
of the boiler.
Remarks
Switching on the heating boiler the increasing
volume of the water can cause a leakage of the
mixer. This is a normal and necessary appearance.
The container of the water must not be under
pressure and particularly on the spout you must
not use aerators or connections different from
the one supplied. The mixer BLANCOLINUS-S-F
ND is normally equipped with non-return valves
according to the DIN-DVGW to be fitted to the
supplying water pipe.
Important
• Do not kink the flexible connector hoses.
• Do not strain the flexible connector hoses.
• Only screw the flexible hoses manually into the
body of the fitting. When connecting the flexible
connector hoses to the service valve or the hot
water tank, the latter must be held firmly in
place to prevent the hoses becoming twisted or
disconnected from the body of the armature.
Maintanance
Jet regulator
1. Loosen jet regulator (12)
2. Flush jet regulator sieve under flowing water
3. Reinsert jet regulatorv
Cartridge replacement
1. Turn off the water at the mains
2. Remove the plug, loosen the screw (2) of the
handle (1)
3. Remove the handle by pulling it
4. Loosen the threading ring (4)
5. Remove the cartridge (6) and replace it
6. Assembly in contrary sequence
Care
In order that your BLANCO kitchen fitting will pro-
vide you with years of pleasure, we recommend
wiping regularly with a dry or damp cloth. Use
clean water or a mild cleaning agent.
On no account should abrasive (neither liquid nor
powder) scouring sponges, or alcohol or acid
based cleaning agents, or other "aggressive"
cleaning agents be used.
The use of proscribed cleaning agents can dama-
ge the finish, such damage is not covered by the
guarantee.
Guarantee
If a claim is made on the guarantee, the claimant
must produce the invoice on which the date of
purchase or installation is given. We reserve the
right to make technical changes.