Technical Product Information BLANCOLINUS-S-F ND / BLANCOLINUS-F ND
Parts list BLANCOLINUS-S-F ND
1 Lever
2 Coloured cap
Screw of the lever
4 Cartridge lock nut
5 Set of O-rings coupling
6 Cartridge
7 Angled pipe
21 Fitting
9 Coupling
10 Mounting set
11 Flexi-hose
21 Hose spray
12 Jet regulator
14 Set of seals angled pipe
15 Seal flexi-hose
17 Non-return valve and housing
16 Nonreturn head
18 Locking bolt angled pipe
19 Spray hose
13 Seal spray hose
20 Weight
22 Fitting
23 Stabilising triangle
24 T-Nipple with seals
Technical Data

Applications

• Can be installed in front of a window
• Simply lift out and put aside
• Warm water tank low pressure
(open warm water heater)
Flow pressure
• Min.
• Max.
• Above 5 bar, a pressure reducer must be
installed.
The kitchen fitting is equipped with a flow rate
controller.
Temperature
• Max. (warm water inlet)
• Recommended (energy saving) 60° C
• Tap: warm-left / cold-right
4
1
Parts list BLANCOLINUS-F ND
1 Lever
4 Cartridge lock nut
5 Set of O-rings coupling
6 Cartridge
7 Spout
9 Coupling
10 Mounting set
11 Flexi-hose
12 Jet regulator
14 Set of seals spout
15 Seal flexi-hose
17 Non-return valve and housing
18 Holding screw spout
23 Stabilising triangle
Before installation and commissioning
Before the fitting is installed, the inlet pipes must
be thoroughly flushed so that no swarf, pieces of
hemp or other contaminants can enter the fitting.
Foreign bodies can enter the fitting through pipes
which have not been flushed, or the water system
in general, and damage the ceramic discs and
O-rings.
0,5 Bar
The installation of a water filter is recommended in
10 Bar
all cases.
Before installing the fitting, unscrew the perlator/
aerator and flush well.
Installation
A tap borehole ø 35 mm is required. Flush all pipes
70° C
well in order to remove the dirt residues. Position
the kitchen fitting in the opening and ensure that
there is a seal between the fitting and the surface
below. In the case of stainless steel sinks, mount
the stabilising triangle from underneath against the
sink to increase the stability. Fasten the fitting with
the mounting set (10 – seal, washer, nut).
2 Coloured cap
Screw of the lever
16 Nonreturn head
3