MAL FUNCTIONS
POSSIBLE CAUSES AND
CORRECTIVE ACTIONS
POSSIBLE CAUSES
No power
Check the connections
Protector
tripped
Reset protection
previously
Defective
motor
Ripair or replace the faulty unit
winding
or
power
cable
Unsuitable fuses or
Replace with suitable units
automatic switch
Supply
voltage
Change motor or supply line
incorrect
One phase is cut out
Reset connections
(three phase motor)
Control
box
or
Replace with our control boxes
capacitors
incorrect
oe other suitable ones
(single phase motor)
Control box in hot
Protect control box from heat
enviroments
sources
Consent inhibited by
Wait for consent or repair
control apparatus
faulty automatism
Sudden failure in the
Replace faulty unit
capacitor
or
other
apparatus
Find out leakage points and
Leakage in the
repair
foot valve or plant
Pressure switch faulty
Reset the pressure switch or
or set incorrectly
replace it
Couple
Ripair and clean unit
overload(friction etc.)
Screen clogged, pump
Pull out unit, clean and
worn.Water
level
overhaul
sunk.
protection against dry-running
CORRECTIVE ACTION
pump;install