Idegis Domotic Serie Manuel D'installation Et D'entretien page 4

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 35
POWER SUPPLY
DESCRIPTION
Standard working voltage
Output (dc)
Production (g/h)
3
Swimming pool (m
)
Warm: 16 – 24°C (60,8 – 75,2 °F)
Hot: +25°C (77 °F)
Flow detector
Salinity /Temperature range
Electrodes
Production control
Cover control
Polarity switch
External control
Salt level protection
ELECTROLYSIS CELL
DESCRIPTION
Minimum recirculation flow
Electrode number
Material
Pipe connections
Max. Recommended pressure
Working temperature
PH / ORP CONTROL
DESCRIPTION
Measure range
Control range
Precision
Calibration
Control output [pH]
pH / ORP sensor
DOM-12 / DOM-12 PH /
DOM-24 / DOM-24 PH /
DOM-12 PLUS
12 A (2x6 A)
10 - 12
60
50
Estimated lifetime: 4.000 – 7.000 hours of operation
Programmable reduction of production from control panel when cover is closed [10% ... 90%]
Programmable from control panel: 2/3 hours + test mode
Two inputs for potential free contact for external flow detector and ORP/RESIDUAL CHLORINE control.
Programmable contact logics from unit control panel
DOM-12 / DOM-12 PH /
DOM-24 / DOM-24 PH /
DOM-12 PLUS
3
2 m
/h
5
DOM-12 PH
DOM-12 PLUS
One output 230 VAC / 500 mA for dosage pump connection
MODEL
DOM-32 / DOM-32 PH /
DOM-24 PLUS
230 V AC, 50/60 Hz.
24 A (2x12 A)
20 -24
100
80
Gas detector
o
3 – 12 g./l. / +15 - 40
C (59 – 104
SELF-CLEANING coated Titanium
0 – 100 % ( 11 production levels)
Input for potential free contact
Automatic production protection
MODEL
DOM-32 / DOM-32 PH /
DOM-24 PLUS
3
4 m
/h
7
Methacrylate derivate
Gluing with PVC adhesive Ø 63 mm
2
1 Kg./cm
o
Less than 40
C (104°F)
MODEL
DOM-24 PH
DOM-24 PLUS
0.0 – 9.9 (pH) / 0 – 999 mV (ORP)
7.0 – 7.8 (pH) / 600 - 850 mV (ORP)
± 0.1 pH / ± 1 mV
Automatic, with calibration solutions
Epoxy body, 12x150 mm., 0-80
blue, range 0 – 12 (pH),
red, range 0 – 1000 mV (ORP)
2
DOM-42 / DOM-42 PH /
DOM-32 PLUS
DOM-42 PLUS
32 A (2x16A)
42 A (6x7A)
25 - 32
160
120
o
F)
DOM-42 / DOM-42 PH /
DOM-32 PLUS
DOM-42 PLUS
3
6 m
/h
7
DOM-32 PH
DOM-42 PH
DOM-32 PLUS
DOM-42 PLUS
o
C (32 – 176°F)
34 - 42
200
160
3
8 m
/h
13