24 VDC delay-disconnection timer. It has a double time scale selectable by SW1 (scale A or B), adjustable time
between 0.1 second and 4 minutes with potentiometer. Push-button activation.
FUNCTIONING : When the start contacts are closed, the relay is activated without timing, when the contacts
are opened, the delay timing begins, after this time the relay is deactivated, remaining in standby until a new
activation.
POWER SUPPLY : Connect the 24 VDC power supply to the POWER terminal respecting ± polarity.
Install a switch for the protection of the circuit and your own safety, according to CE standard.
Before activating the switch, make the rest of the circuit connections.
To supply 230 V AC you can use our recommended power supply FE-115.
TIMING : to adjust the delay timing, select time scale with SW 1 and adjust time with the potentiometer. Once
these settings are selected, the timer is ready for use.
TIMER ACTIVATION : It is activated with a button or switch connected to the Start input.
Temporisateur de déconnexion 24 VDC. Il dispose d'une double échelle de temps sélectionnable par SW1
(échelle A ou B), temps réglable entre 0,1 seconde et 4 minutes avec potentiomètre. Activation par bouton-
poussoir .
TEMPO. RETARDER by DISCONNECTION
TEMPO. RALENTISSEUR par DECONNEXION
TEMPO. RETARDADOR por DESCONEXION
TEMPO. RETARDADOR per DESCONEXIO
www.cebek.com
1 sec. To 4 min.
I-38.24
Technical characteristics
Voltage : 24 V Dc
Medium Consumption : 40 mA
Timing configuration scale A : 0,1 to 24 secs.
Timing configuration scale B : 1 sec to 4 mins.
Activation : Pushbutton
Output type : Relay - NO / NC
Max. Output load : 7A ( 2A for inductive loads)
Operating Indicator Led : Yes.
Protection Inversion Polarity : Yes.
Sizes : 72 x 42 x 20
Weight : 28,5 gr.
Din rail : C-7564
-