AUDIO VIDEO IP 6 PB - 10 PB DOOR ENTRY STATION
FUNCTIONS
The door entry station is designed to communicate, via the IP network, with all the other stations in the IP Intercom
range (XELLIP, CAP IP ...), with a Softphone, a sip phone, or any other element compatible with the SIP standard.
General functions of the entry station
• Configuring a network connection.
• Configuring an SIP account
• Setting the date and time manually or via an NTP server
• Management of audio and video communications (according to version)
↘ Setting a level of priority for the device
↘ Setting a call and communication timeout
↘ Automatic answering with and without delay
↘ Activating privacy mode for automatic answering
Audio interface functions
• Configuring the volume of the loudspeakers, microphone and audio induction loop
• Configuring the Anti Echo Acoustic (AEC)
• Configuring the RTP port number
• Enabling/Disabling audio codecs
• Configuring ring tones and tones
• Configuring DTMF commands used to control the local relay, for example
• Configuring noise detection used to activate a call, for example
• Switching to simplex through a DTMF command from the calling party station
↘ '*' switches to listening simplex
↘ '#' switches to speech simplex
↘ '0' is used to return to standard operation
Video interface functions
• Resolution selection (QCIF/QVGA/CIF/VGA/HD)
• Activating bandwidth management
• Configuring the RTP port number
• Enabling/Disabling video codecs
Programmable button functions
Each button can be programmed and is used to:
• Call 1 to 10 stations simultaneously or with timeout
• Control the local relay, the relay of the station on a call
• Send a DTMF code
• End a call
'Scroll call' button functions
• This button is the main button of stations with name scrolling module.
• Generally, it can confirm the current action.
• When the entry station is idle, this button can be programmed to call 1 to 10 stations simultaneously or with
timeout and display a help menu on how to use the entry station.
Badge reader functions
• Badge type configuration
• Reader inhibition
• Local access control on the station
• Supervised access control (by using CastelAccès)
Digital input interface functions
• STATUS or COUNTER input configuration
• Input active status configuration (open or closed contact)
• Recognition timeout configuration for a status change (debouncing function)
• Counter threshold configuration
• Input inhibition
Technical data sheet no. 604-0091D