SAFETY RULES
RULES AND/OR INSTRUCTIONS MARKED WITH THIS
SYMBOL ARE ASSOCIATED WITH SAFETY!
The following rules and precautions help you to avoid the
risks associated with use of this appliance:
• the appliance must be installed according to the rules in
section 2.2 of this handbook;
• installation must be carried out in conformity with all rules at
the workplace, as well as with all domestic and European
regulations;
• make sure the flue is suitable before connecting the
cooker to it;
• it is strictly forbidden to use chemical products for lighting
the cooker – such as alcohol, oil, petrol, etc.;
• do not put in too much fuel as this can produce excessive
heat and overheat the appliance, causing potential
damage;
1. IDENTIFICATION OF THE APPLIANCE
1.1 IDENTIFICATION PLATE
There is an identification plate at the back of the appliance that indicates model and serial number.
1.2 TABLE OF TECHNICAL SPECIFICATIONS
CLASSIC
TECHNICAL SPECIFICATIONS
External dimensions: LxDxH
Heating plate: LxD
Net weight/with packaging
Required flue depression
Nominal thermal output
Co at 13% O ²
Mean flue gas temperature
Flue gas mass flow
Efficiency
DOMINO
TECHNICAL SPECIFICATIONS
External dimensions: LxDxH
Heating plate: LxD
Net weight/with packaging
Required flue depression
Nominal thermal output
Co at 13% O ²
Mean flue gas temperature
Flue gas mass flow
Efficiency
ECO
TECHNICAL SPECIFICATIONS
External dimensions: LxDxH
Heating plate: LxD
Net weight/with packaging
Required flue depression
Nominal thermal output
Co at 13% O ²
Mean flue gas temperature
Flue gas mass flow
Efficiency
• the cooking plate can reach high temperatures of up to
• do not put any plastic bottles or spray cans on top or in the
• warn children of the risks and keep them away from the
• place sheet metal protection on the floor under the fill
• use only natural fuel such as: wood, blocks of compressed
• do not burn any plastics, treated wood (e.g. chipboard)
• clean the flue on a regular basis.
um
F 450
cm
45x60x86
cm
31x45
kg
115/125
mbar
0,12
kw
5
%
0,21
°C
262
g/s
12
%
70
um
D6
cm
60x60x86
cm
45x48
kg
180/195
mbar
0,12
kw
7,5
%
0,09
°C
261
g/s
10,6
%
75,5
um
E60
cm
60x60x86
cm
48x45
kg
130/140
mbar
0,12
kw
6,5
%
0,15
°C
263
g/s
10,9
%
71
14
around 400 °C; be careful therefore and do not touch it
without appropriate protection – the same applies to the
other components such as the firebox and oven doors and
their respective handles, glass surfaces and the flue pipe;
immediate vicinity of the appliance (risk of fire and
explosion);
stove when it is in operation;
opening, especially if the floor is made of lino or wood;
wood and lignite briquettes;
or textiles;
F 6000
60x60x86
48x45
170/180
0,12
7,5
0,21
262
11,8
75,5
D6maxi
60x60x86
45x48
180/195
0,12
7,5
0,09
261
10,6
75,5
E80
E90
60x60x86
80x60x86
68x45
74x45
165/180
175/190
0,12
0,12
9
9
0,13
0,13
228
228
13,7
13,7
71
71
F 800
F 900/A900
80x60x86
90x60x86/51
68x45
74x45
180/200
180/200
0,12
0,12
10
10
0,21
0,21
303
241
11,6
11,6
73
73
D8
D8maxi
80x60x86
80x60x86
66x48
66x48
195/215
195/215
0,12
0,12
10
10
0,12
0,12
293
293
14,9
14,9
72,5
72,5
Internal diameter
of test flue:
D = 150 mm
FLUE CONNECTION
Above
Ø 13 mm
Rear
Ø 14 mm
Side
Ø 14 mm