LEVEL ADjUSTMENT/BOILER
Refilling is carried out each time the level probe senses a low water
level in the boiler. During normal level recovery, the heater remains enabled
for heating.
If during filling the level probe located in the tank should remain exposed,
the system immediately stops refilling operations and the signal lamp (2 Fig.
9) starts blinking together with an intermittent acoustic signal.
TANK
Each time the tank level probe senses a low water level, the system
immediately stops refilling operations and the signal lamp (2 Fig. 9) starts
blinking together with an intermittent acoustic signal.
Refill the tank to reset the alarm.
IMPORTANT! AVOID THE USE OF DISTILLED OR DE-MINERALIZED WATER SO
AS NOT TO jEOPARDIZE THE EFFICIENT FUNCTION OF THE GENERATOR.
STEAM EjECTION
The steam is released by pressing the steam trigger (1)
The steam trigger (1) may be locked with the safety catch on the grip. By
pressing the safety lock on the left side of the grip will block the steam
trigger (5), pressing on the opposite side will release it (6) (Fig. 16).
STEAM AND CHEMICAL EjECTION
Enable the chemical ejection by switch (4 Fig. 17).
With the chemical ejection enabled the chemical is automatically ejected
with the steam when the trigger (1 Fig. 16) is pressed.
When chemical is released the light (5 Fig. 17) is ON.
During operation, the machine may reach high temperatures. Do not touch
the parts that come into direct contact with steam.