8. TROUBLESHOOTING

NB!
All troubleshooting and servicing that requires the toilet to be disconnected from the flue pipe or gas line
must be performed by authorized personell only, in accordance with all state, municipal and local codes. If
you are unsure of the regulations in your area, please contact your nearest dealer or service representative
for further instructions.
The power should be disconnected when performing all servicing and maintenance on the toilet.
OUT OF GAS
Failure to incinerate properly and a flashing yellow display lamp may indicate that the propane
tank is empty, and has to be re-filled/replaced. Natural gas must not be used.
RESETTING THE TOILET SYSTEM
During cleaning and troubleshooting, resetting the electronics may
sometimes be helpful. You can do this by pressing the Start but-
ton. This will cause a short beep to sound. Hold down the button
for about 8 seconds until you hear a long beep, then release the
button.
BLACK CHARCOAL RESIDUE
The ash should be grey when properly incinerated. Black lumps indicate insufficient combustion and may be re-
lated to restrictions in the airflow or insufficient air being drawn into the chamber. Check your installation. When
performing maintenance and cleaning the ash container, make sure that you don't leave any residue that may
cause problems.
ERROR MESSAGES
When lights are flashing, you should look for the reason, and fix the problem before using the toilet. You must
take immediate action in the event of any irregularities such as odours, poor incineration or system failures,
in order to avoid damage and unnecessary repair costs.