ADA-1031
Guide to Installation and Operation
Menu Introduction
Most parameters are accessed and changed via an easy-to-use menu. The flow chart below outlines the entire ADA-1031
menu path. Each menu is described throughout this section.
The procedure and the operation mode are described in the common paragraph of the DENSITÉ Manual. The menu
organisation is made out of a main menu and several sub-menus. A press on the [SELECT] front panel push button accesses to
the menu. A lack of activity turns off the display. Default values are written with bold characters.
STATUS
NO SIGNAL DELAY
SIGNAL THRESHOLD
OVERLOAD THRESHOLD
LEVEL
CONFIGURE ALARM
FACTORY DEFAULT
Menu Description
{STATUS}
Displays status of the different board alarms. The higher-level
alarm is displayed, even if not configured to activate the
STATUS Led. ALL OK indicates an absence of alarm.
REAR PANEL ERROR Indicates an absence of the rear
panel or an incompatibility between
the module and the rear panel. The
STATUS led turns on flashing red.
Indicates an internal signal level
OVERLOAD
higher than the selected threshold.
Indicates an internal signal level lower
NO SIGNAL
than the selected threshold during a
user defined period.
MODE SINGLE/DUAL Displays the module configuration.
REAR PANEL ERROR, OVERLOAD 1, OVERLOAD 2, OVERLOAD 1&2,
NO SIGNAL 1, NO SIGNAL 2, NO SIGNAL 1&2, ALL OK
LEVEL 1
LEVEL 2
LEVEL 1&2
OVERLOAD 1
ALARM LEVEL
ALARM REPORT
OVERLOAD 2
ALARM LEVEL
ALARM REPORT
NO SIGNAL 1
ALARM LEVEL
ALARM REPORT
NO SIGNAL 2
ALARM LEVEL
ALARM REPORT
RESTORE
{NO SIGNAL DELAY}
{OVERLOAD THRESHOLD}
SINGLE, DUAL
0, ..., 15, ..., 255 [sec]
-48, -42, -36, -30, -24
-9, ..., +24
-96, ..., 0, ..., +31.5
-96, ..., 0, ..., +31.5
-96, ..., 0, ..., +31.5
GREEN, YELLOW, RED, FLASH RED
NONE, GPI
GREEN, YELLOW, RED, FLASH RED
NONE, GPI
GREEN, YELLOW, RED, FLASH RED
NONE, GPI
GREEN, YELLOW, RED, FLASH RED
NONE, GPI
Signal absence is declared when
NO SIGNAL DELAY
the level signal is lower than the
signal threshold during the selected
period, it can be adjusted from 0 to
255 s. The default value is set to
15 s.
The presence signal threshold can
SIGNAL THRESHOLD
be adjusted from –48 to –24 dBu by
6 dBu steps. The default value is
–36 dBu.
OVERLAOD THRESHOLD The overload signal threshold can
be set from –9 to +24 dBu. The
default value is +24 dB.
[dBu]
[dBu]
[dB]
[dB]
[dB]