Remote control safety functions
Blocking protection
The remote receiver includes a function that automatically blocks motor operation, cutting
current to the motor 30 seconds after detecting an obstruction in front of the fan that pre-
vents normal operation. When this happens, you must remove the obstacles blocking the fan.
Then, press the off button on the remote control to reset the receiver. Now you can continue
to use the fan normally.
Note: Unless you remove the obstruction blocking the fan, it will not operate correctly.
Overload prtection
If the fan's receiver detects that the motor is operating at greater than 80W (this indicates an
overload), current to the motor will be cut automatically, which will immediately stop the fan.
To reset the receiver, press the off button on the remote control.
Note: If the receiver goes into protection mode again, this may indicate a motor defect.
Contact the supplier immediately. The duration of the warranty is indicated in the warranty
document provided in this manual.
Rotation direction: summer and winter options
The sliding switch controls the direction, whether clockwise or counterclockwise.
Summer option/down -
kwise. The downwards air current creates a refreshing effect as indicated in diagram A.
Winter option/up -
cending air current pushes hot air away from the fan area near the ceiling, as indicated in diagram B. This
allows you to use less central heating.
Note: Turn off the fan, lower the differential, and wait for it to come to a complete stop before changing
the blade rotation direction with the sliding switch.
Environmental protection
Do not throw away electrical products together with household waste. We ask you
to recycle the packaging at the collection points provided for this purpose. Contact
local authorities or your provider for recycling advice. Thank you for recycling at the
collection points provided for this manual.
or left-facing position (depending on the model) - The fan runs countercloc-
or right-facing position (depending on the model) - The fan runs clockwise. An as-
EN
13