Maintenance
If faucet leaks from under handle:
Remove handle and ensure cap (1) is tight.
If leak persists–SHUT OFF WATER
SUPPLIES. Replace Ball Assembly
(2)–Repair Kit RP70 and Cam & Packing
(3)–Repair Kit RP61.
If faucet leaks from spout outlet:
SHUT OFF WATER SUPPLIES. Replace
Ball Assembly (2)–Repair Kit RP70 and
Seats & Springs (4)–Repair Kit RP4993.
If faucet exhibits very low flow
A. Remove and clean Aerator (5), or
B. SHUT OFF WATER SUPPLIES. Clean
Seats and Springs (4) of any debris.
If spray attachment does not
function properly:
SHUT OFF WATER SUPPLIES. Remove
Diverter Assembly (6) and clean.
If condition persists–SHUT OFF WATER
SUPPLIES. Replace Diverter Assembly (6)–
Repair Kit RP63136.
If faucet leaks from base of spout:
SHUT OFF WATER SUPPLIES. Remove
spout and replace Spout O-Rings (7)–Repair
Kit RP25.